• Pacing Clin Electrophysiol · Aug 1993

    Technical and clinical problems in patients with simultaneous implantation of a cardiac pacemaker and spinal cord stimulator.

    • M Romanó, F Zucco, M R Baldini, and B Allaria.
    • Department of Cardiology, S. Corona Hospital, Garbagnate Milanese, Italy.
    • Pacing Clin Electrophysiol. 1993 Aug 1;16(8):1639-44.

    AbstractSpinal cord stimulators are used to relieve pain associated with peripheral ischemia and angina pectoris. In patients with both permanent pacemaker (PPM) and a spinal cord stimulator (SCS), electromagnetic signals from the SCS may inhibit the PPM. A bipolar PPM configuration is preferred to minimize myopotential or electromagnetic interference but patients have safely had unipolar devices implanted. We report ten patients (six males and four females; median age 73.3 years) with both a SCS and a PPM implanted between 1987-1991. Intermittent interference with one PPM (Ela Medical Model Opus 3001) was noted after an increase in the output voltage of the SCS for continued clinical efficacy. Inhibition was output voltage dependent, and reversion to the noise mode was frequency dependent. Sensitivity to both could be managed by changing the pacemaker sensitivity. Interference with pacemaker function occurred if the SCS output was set above a voltage and pulse duration which resulted in a product of these values above 1.9-2 mVs. Seven VVI, one VDD, and two DDD PPM had been implanted. In five patients both PPM and SCS were unipolar. In two patients the SCS was bipolar and the PPM unipolar, in two patients a bipolar PPM was associated with a bipolar SCS and with one patient, a unipolar SCS. Multiprogrammable and/or bipolar PPMs should be implanted in a patient with a SCS to allow reprogramming of the PPM and to minimize the risk of inter-device interference. Inhibition of the PPM may occur at different SCS stimulation frequencies. The frequency at which inhibition occurs varies with different models of implanted pacemaker.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.