Eur J Cardiothorac Surg · Jan 2016
Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable left ventricular assist device placement.
- Jeremy Leidenfrost, Sunil Prasad, Akinobu Itoh, Christopher P Lawrance, Jennifer M Bell, and Scott C Silvestry.
- Division of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Saint Louis, MO, USA.
- Eur J Cardiothorac Surg. 2016 Jan 1; 49 (1): 73-7.
ObjectivesCardiogenic shock from refractory right ventricular (RV) failure during left ventricular assist device placement is associated with high morbidity and mortality. The addition of extracorporeal membrane oxygenation to RV mechanical assistance may help RV recovery and lead to improved outcomes.MethodsWe retrospectively reviewed all implanted continuous-flow left ventricular assist devices from April 2009 to June 2013. RV mechanical support was utilized for RV failure defined as haemodynamic instability despite vasopressors, pulmonary vascular dilators and inotropic therapy. RV assist devices were utilized with and without in-line membrane oxygenation.ResultsDuring the study period, 267 continuous-flow left ventricular assist devices were implanted. RV mechanical support was utilized in 27 (10%) patients; 12 (46%) had the addition of in-line extracorporeal membrane oxygenation. The mean age of patients with a right ventricular assist device with membrane oxygenation was lower than that in patients with a right ventricular assist device alone (45.6 ± 15.9 vs 64.6 ± 6.5, P = 0.001). Support was weaned in 66% (10 of 15) of patients with right ventricular assist device (RVAD) alone vs 83% (10 of 12) of those with RVAD with membrane oxygenation (P = 0.42). The RVAD was removed after 10.4 ± 9.4 vs 5 ± 2.99 days for patients with a RVAD with membrane oxygenation (P = 0.1). Patients with RVAD with membrane oxygenation had a 30-day mortality rate of 8 vs 47% for those with RVAD alone (P = 0.04). The survival rate after discharge was 86, 63 and 54% at 3, 6 and 12 months for both groups combined.ConclusionsPatients with a RVAD with membrane oxygenation support for acute RV failure after continuous-flow left ventricular assist device implantation had a lower 30-day mortality than those with a RVAD alone. Patients who survive to discharge have a reasonable 1-year survival. Combining membrane oxygenation with RVAD support appears to offer a short-term survival benefit in patients with RV failure after continuous-flow left ventricular assist device implantation.© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.