J Spinal Disord Tech · Feb 2015
Case ReportsProximal instrumented vertebral body chance fracture after pedicle screw instrumentation in a thoracic kyphosis patient with osteoporosis.
- Xiaobang Hu and Isador H Lieberman.
- Scoliosis and Spine Tumor Center, Texas Back Institute, Plano, TX.
- J Spinal Disord Tech. 2015 Feb 1;28(1):31-6.
Study DesignWe present a case of proximal vertebral body chance fracture after pedicle screw instrumentation and fusion in a 67-year-old woman with osteoporosis and thoracic kyphosis.ObjectiveTo report the rare and unique complication of proximal vertebral body chance fracture after pedicle screw instrumentation and fusion in a kyphosis patient.Summary Of Background DataPedicle screw instrumentation has been associated with complications not limited to neurological or vascular injury, loss of curve correction, intraoperative pedicle fracture or loosening, dural laceration, deep infection, and pseudarthrosis. To the best of our knowledge, there are no previous reports describing a chance-type fracture generated by a pedicle screw fixation at the proximal end of a construct.MethodsA 67-year-old woman suffered from progressive thoracic kyphosis and mid thoracic pain presented 2 weeks after pedicle screw instrumentation and correction. She developed a vertebral body fracture at the proximal end of the instrumentation construct. Surgical intervention, including removal of the screws in the fractured vertebrae and extension of the instrumented fusion across the cervicothoracic junction, effectively restored the physiological sagittal alignment.ResultsPostoperatively, at 12-month follow-up, the patient is doing exceptionally well with near-complete relief of back pain and an excellent maintenance of correction.ConclusionsChance fracture in osteoporotic bone at the proximal end of a construct due to a pedicle screw is a rare complication but it may result in catastrophic consequences. Early recognition of this complication, reduction of the fraction-dislocation, and an extension of the instrumentation can be utilized for realignment and long-term stabilization.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.