• J Spinal Disord Tech · Jun 2014

    Biomechanical analysis of various footprints of transforaminal lumbar interbody fusion devices.

    • Ahmad Faizan, Ali Kiapour, Ata M Kiapour, and Vijay K Goel.
    • *Custom Spine Inc., Parsippany, NJ †Departments of Bioengineering and Orthopaedic Surgery, Engineering Center for Orthopaedic Research Excellence (E-CORE), Colleges of Engineering and Medicine, University of Toledo, Toledo, OH.
    • J Spinal Disord Tech. 2014 Jun 1;27(4):E118-27.

    Study DesignA biomechanical finite element modeling study of the human lumbar spine.ObjectiveTo evaluate the effects of a transforaminal interbody device's footprint on lumbar spine biomechanics to further examine the potential subtle biomechanical differences not captured in previous studies.Summary Of Background DataIn recent years, the evolution of interbody fusion devices has provided the surgeons with a multitude of options. An articulating transforaminal lumbar interbody fusion (TLIF) device is developed to overcome the surgical challenges associated with insertion of a large footprint interbody device through a small incision.MethodsA finite element model of the L3-S1 lumbar segment was modified to simulate replacement of various TLIF constructs with different cage designs including an articulating vertebral interbody (AVID) TLIF device and a generic TLIF device placed in different configurations. The instrumented models were subjected to a 400 N follower load along with a 10 N m bending moment at different physiological planes. The kinematics, loads, and stresses were compared among various models.ResultsSimulated cage designs provided similar kinematical stability within the treated segments. However, the articulating and double TLIF implants allowed for better load sharing through the anterior column. These implants resulted in lower endplate and pedicle screw stresses and in more homogenous stress distribution across the peripheral region of the endplate.ConclusionsAn articulating, large footprint, peripherally placed TLIF device affords substantial biomechanical advantages. This device may be able to reduce the incidence of subsidence because of its ability to reduce and distribute the endplate stresses in the stronger peripheral region. It may also reduce the posterior hardware failure incidence owing to its ability to reduce the screw stresses as compared with traditional TLIF. Although double TLIF has been demonstrated to have similar biomechanical advantages as the AVID, complications associated with double TLIF (ie, larger surgical incision, longer surgical procedure, placement and alignment challenges) support AVID as a better optimized alternative.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.