    [Air conditioning with a high-performance HME (heat and moisture exchanger)--an effective and economical alternative to active humidifiers in ventilated patients. A prospective and randomized clinical study].

    • J Rathgeber, D Henze, and K Züchner.
    • Zentrum Anaesthesiologie, Rettungs- und Intensivmedizin, Georg-August-Universität Göttingen.
    • Anaesthesist. 1996 Jun 1; 45 (6): 518-25.

    AbstractHeat and moisture exchangers (HME) are used as artificial noses for intubated patients to prevent damage resulting from dry and cold inspired gases. HME collect a large fraction of the heat and moisture of the expired air, adding them to the subsequent inspired breath. In a prospective clinical study the air conditioning capacity of a heated humidifier was compared with a hygroscopic HME. METHODS. The water content of the ventilated air of 49 intensive care patients requiring artificial ventilation with tidal volumes between 440 and 1,190 ml (mean 658 +/- 148 ml) was examined. Each patient was ventilated in sequence with an HME (DAR Hygrobac S) and a heated humidifier (Fisher & Paykel MR 630 B). The temperature of the air in the inspiratory limb was maintained at 34 degrees C. The water content of the ventilated air was determined under steady-state conditions directly at the tracheal tube or between tracheal tube and HME using a new, high-resolution humidity meter. The results were compared with the absolute water loss of the exhaled air at the gas outlet of the ventilator as an expression of the water loss from the lower airways. Airway resistance was calculated by a standard formula. The daily running costs for both HME and heated humidifier were estimated. RESULTS AND DISCUSSION. Moisture retention was equivalent in both the HME and the heated humidifier (33.7 +/- 1.85 bzw. 34.1 +/- 2.62 mgH2O/l). These data show that modern HMEs are able to maintain physiological air-conditioning even in long-term ventilated patients. The small increase in airway resistance associated with HMEs (3.1 +/- 2.5 mbar/l.s) has to be noted in difficult weaning procedures. Both labour and costs per day are significantly less with HMEs (8.60 vs. 21.70 DM).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.