• Anesthesia and analgesia · Dec 1998

    Comparative Study

    A comparison of pharyngeal mucosal pressure and airway sealing pressure with the laryngeal mask airway in anesthetized adult patients.

    • J Brimacombe and C Keller.
    • Department of Anaesthesia and Intensive Care, Cairns Base Hospital, Australia. 100236,2343@compuserve.com
    • Anesth. Analg. 1998 Dec 1;87(6):1379-82.

    UnlabelledWe measured pharyngeal mucosal pressures at six different locations on the laryngeal mask airway (LMA) and tested the hypothesis that the efficacy of the seal is not related to pharyngeal mucosal pressure. Twenty anesthetized, paralyzed adult patients were studied. Microchip sensors were attached to the size 5 LMA at locations corresponding to the lateral and posterior pharynx, the hypopharynx, the pyriform fossa, the base of tongue, and the oropharynx. Mucosal pressures and airway sealing pressures were recorded during inflation of the cuff from 0 to 40 mL in 10-mL increments. The highest mean mucosal pressure was in the oropharynx (26 cm H2O), and the lowest was in the posterior pharynx (2 cm H2O). Mucosal pressures increased with increasing intracuff pressure and cuff volume, but the rate of increase varied among locations. Airway sealing pressure increased with increasing intracuff volume from 0 to 10 mL (P < 0.0001) and 10 to 20 mL (P = 0.0001), was unchanged from 20 to 30 mL, and decreased from 30 to 40 mL (P = 0.005). The airway sealing pressure was higher than pharyngeal mucosal pressure until the intracuff volume was > or =30 mL. There was no correlation between mucosal pressures and airway sealing pressure at any location. We conclude that the efficacy of the seal is not related to pharyngeal mucosal pressure. Pharyngeal mucosal pressures are generally lower than those considered safe for the tracheal mucosa during prolonged intubation.ImplicationsWe measured pharyngeal mucosal pressures at six different locations on the laryngeal mask airway and showed that the efficacy of the seal is not related to pharyngeal mucosal pressure. Pharyngeal mucosal pressures are generally lower than those considered safe for the tracheal mucosa during prolonged intubation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…