-
- D W Coombs, R W Colburn, J A DeLeo, and B B Twitchell.
- Department of Anesthesiology, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03756.
- Reg Anesth. 1993 Jul 1;18(4):230-7.
ObjectiveThe authors report the use of multiple implanted intraspinal port and catheter systems per test animal to study the in vivo functional characteristics and reliability of a new implantable spinal drug delivery port system.MethodsFour ewes were each implanted with two epidural and one subarachnoid silicone elastomer catheters at the lumbar level. Each catheter was connected in series to one of three Therex filtered spinal delivery ports implanted subcutaneously in a similar grid pattern in each ewe to facilitate percutaneous identification. Saline (2 ml) was injected 3 times weekly in each port. The ease of injection and behavioral responses were recorded for 207-213 days of implantation until sacrifice/necropsy.ResultsAll ports functioned reliably during the study. However, injection through two of the four subarachnoid catheters resulted in behavioral withdrawal responses intermittently. This behavioral pattern was much less common after epidural port injections. All four subarachnoid and four of eight epidural port and catheter systems were tested with local anesthetic just before sacrifice. Motor block was observed in three of four subarachnoid and three of four epidural port and catheter systems tested. Integrity of the other four epidural ports was tested by injection of methylene blue at sacrifice. This dye did not distribute in the epidural space in one of the latter four epidural ports (not local anesthetic tested) because of a concentric fibrotic reaction about the catheter. Similar fibrotic reactions surrounded the catheters that failed a functional test with local anesthetic.ConclusionsThe implantable intraspinal port system tested functions reliably under repetitive percutaneous access. However, filtering such ports, though desirable to prevent entry of debris into the spinal canal, did not eliminate pericatheter chronic subarachnoid and epidural reaction. The number of test animals required to test 12 ports chronically was reduced by two-thirds without undue trauma to the individual test subject. Chronic percutaneous injection of an implanted subarachnoid system is feasible but may be associated with behavioral effects similar to that seen with chronic epidural systems. Fibrosis around chronic silicone catheters limited functional utility in one-fourth of the implanted test systems. Further study of the potential reactivity of chronic epidural and subarachnoid catheters is indicated.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.