• Eur J Cardiothorac Surg · Jun 2007

    Midterm follow-up of the status of Gore-Tex graft after extracardiac conduit Fontan procedure.

    • Cheul Lee, Chang-Ha Lee, Seong Wook Hwang, Hong Gook Lim, Soo-Jin Kim, Jae Young Lee, Woo-Sup Shim, and Woong-Han Kim.
    • Department of Thoracic and Cardiovascular Surgery, Sejong Heart Institute, Sejong General Hospital, 91-121 Sosa Bon 2-dong, Sosa-ku, Bucheon-shi, Kyungki-do 422-232, South Korea.
    • Eur J Cardiothorac Surg. 2007 Jun 1;31(6):1008-12.

    ObjectiveExtracardiac conduit Fontan procedure has some theoretical advantages over other types of Fontan procedures, such as optimized flow dynamics, a lower frequency of arrhythmias, and technical ease of procedure. However, lack of growth potential and thrombogenicity of the artificial conduit is the main concern and can possibly lead to reoperation for the conduit stenosis. In this study, we investigated the change and the status of the Gore-Tex graft used in extracardiac conduit Fontan procedure.MethodsBetween 1996 and 2005, 154 patients underwent extracardiac conduit Fontan procedure using Gore-Tex graft. Among these, 46 patients underwent cardiac catheterization during follow-up period. We measured the internal diameter of the conduit and inferior vena cava angiographically.ResultsMean follow-up duration was 36.1+/-19.7 months. The conduit diameter used was 16 mm in 10 patients, 18 mm in 16, 20 mm in 14, 22 mm in 4, and 24 mm in 2 patients. The mean conduit-to-inferior vena cava cross-sectional area ratio was 1.25+/-0.33. According to the conduit size used, this ratio was 1.03+/-0.17 for 16 mm conduits, 1.33+/-0.37 for 18 mm, 1.33+/-0.36 for 20 mm, 1.28+/-0.26 for 22 mm, and 1.05+/-0.06 for 24 mm conduits (p<0.05, 16 mm vs 18 mm and 20 mm). The mean percent decrease of the conduit cross-sectional area was 14.3+/-8.5%, and this did not differ significantly according to the conduit size (p=0.82). Follow-up duration and the percent decrease of the conduit cross-sectional area did not show significant correlation (r=0.22, p=0.14). There was no reoperation due to conduit stenosis.ConclusionsDuring midterm follow-up of about 3 years, the conduit cross-sectional area decreased by 14%, and this did not differ according to the conduit size used. The extent of decrease of the conduit cross-sectional area remained stable irrespective of the follow-up duration. Sixteen millimeters conduit showed no evidence of clinically significant stenosis, but careful follow-up is warranted because of the possible conduit stenosis relative to the patients' somatic growth.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.