• Journal of critical care · Apr 2014

    Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients.

    • Abele Donati, Andrea Carsetti, Stefania Tondi, Claudia Scorcella, Roberta Domizi, Elisa Damiani, Vincenzo Gabbanelli, Christopher Münch, Erica Adrario, Paolo Pelaia, and Maurizio Cecconi.
    • Anesthesia and Intensive Care Unit, Department of Biomedical Sciences and Public Health, Università Politecnica delle Marche, via Tronto 10/A, 60126, Ancona, Italy. Electronic address: a.donati@univpm.it.
    • J Crit Care. 2014 Apr 1;29(2):260-4.

    PurposeMany mini-invasive devices to monitor cardiac output (CO) have been introduced and, among them, the pressure recording analytical method (PRAM). The aim of this study was to assess the agreement of PRAM with the intermittent transpulmonary thermodilution and continuous pulmonary thermodilution in measuring CO in hemodynamically stabilized patients.Materials And MethodsThis is a prospective clinical study in a mixed medical-surgical intensive care unit (ICU) and in a postcardiac surgical ICU. Forty-eight patients were enrolled: 32 patients to the medical-surgical ICU monitored with PiCCO (Pulsion Medical System AG, Munich, Germany) and 16 were cardiac patients monitored with Vigilance (Edwards Lifesciences, Irvine, CA).ResultsA total of 112 measurements were made. Ninety-six comparisons of paired CO measurements were made in patients hospitalized in medical-surgical ICU; 16, in cardiac surgical patients. The mean Vigilance-CO was 4.49 ± 0.99 L/min (range, 2.80-5.90 L/min), and the mean PRAM-CO was 4.27 ± 0.88 L/min (range, 2.85-6.19 L/min). The correlation coefficient between Vigilance-CO and PRAM-CO was 0.83 (95% confidence interval, 0.57-0.94; P < .001). The bias was 0.22 ± 0.55 L/min with limits of agreement between 0.87 and 1.30 L/min. The percentage error was 25%. Mean TP-CO was 6.78 ± 2.04 L/min (range, 4.12-11.27 L/min), and the mean PRAM-CO was 6.11 ± 2.18 L/min (range, 2.82-10.90 L/min). The correlation coefficient between PiCCO-CO and PRAM-CO was 0.91 (95% confidence interval, 0.83-0.96; P < .0001). The bias was 0.67 ± 0.89 L/min with limits of agreement -1.07 and 2.41 L/min. The coefficient of variation for PiCCO was 4% ± 2%, and the coefficient of variation for PRAM was 10% ± 8%. The percentage error was 28%.ConclusionsThe PRAM system showed good agreement with pulmonary artery catheter and PiCCO in hemodynamically stabilized patients.Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.