Observational Study
Association between Prehospital CPR Quality and End-Tidal Carbon Dioxide Levels in Out-of-Hospital Cardiac Arrest.
- Ryan A Murphy, Bentley J Bobrow, Daniel W Spaite, Chengcheng Hu, Robyn McDannold, and Tyler F Vadeboncoeur.
- Prehosp Emerg Care. 2016 May 1; 20 (3): 369-77.
IntroductionInternational Guidelines recommend measurement of end-tidal carbon dioxide (EtCO2) to enhance cardiopulmonary resuscitation (CPR) quality and optimize blood flow during CPR. Numerous factors impact EtCO2 (e.g., ventilation, metabolism, cardiac output), yet few clinical studies have correlated CPR quality and EtCO2 during actual out-of-hospital cardiac arrest (OHCA) resuscitations. The purpose of this study was to describe the association between EtCO2 and CPR quality variables during OHCA.MethodsThis is an observational study of prospectively collected CPR quality and capnography data from two EMS agencies participating in a statewide resuscitation quality improvement program. CPR quality and capnography data from adult (≥18 years) cardiac resuscitation attempts (10/2008-06/2013) were collected and analyzed on a minute-by-minute basis using RescueNet™ Code Review. Linear mixed effect models were used to evaluate the association between (log-transformed) EtCO2 level and CPR variables: chest compression (CC) depth, CC rate, CC release velocity (CCRV), ventilation rate.ResultsAmong the 1217 adult OHCA cases of presumed cardiac etiology, 925 (76.0%) had a monitor-defibrillator file with CPR quality data, of which 296 (32.0%) cases had >1 minute of capnography data during CPR. After capnography quality review, 66 of these cases (22.3%) were excluded due to uninterpretable capnography, resulting in a final study sample of 230 subjects (mean age 68 years; 69.1% male), with a total of 1581 minutes of data. After adjustment for other CPR variables, a 10 mm increase in CC depth was associated with a 4.0% increase in EtCO2 (p < 0.0001), a 10 compression/minute increase in CC rate with a 1.7% increase in EtCO2 (p = 0.02), a 10 mm/second increase in CCRV with a 2.8% increase in EtCO2 (p = 0.03), and a 10 breath/minute increase in ventilation rate with a 17.4% decrease in EtCO2 (p < 0.0001).ConclusionWhen controlling for known CPR quality variables, increases in CC depth, CC rate and CCRV were each associated with a statistically significant but clinically modest increase in EtCO2. Given the small effect sizes, the clinical utility of using EtCO2 to guide CPR performance is unclear. Further research is needed to determine the practicality and impact of using real-time EtCO2 to guide CPR delivery in the prehospital environment.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.