• J Burn Care Rehabil · Jan 2004

    The 2003 Carl A Moyer Award: real-time metabolic monitors, ischemia-reperfusion, titration endpoints, and ultraprecise burn resuscitation.

    • T D Light, James C Jeng, A K Jain, K A Jablonski, D E Kim, T M Phillips, A G Rizzo, and M H Jordan.
    • Department of Surgery, Washington Hospital Center, Washington, DC 20010, USA.
    • J Burn Care Rehabil. 2004 Jan 1;25(1):33-44.

    AbstractReal-time metabolic monitoring of varied vascular beds provides the raw data necessary to conduct ultraprecise burn shock resuscitation based on second-by-second assessment of regional tissue perfusion. It also illustrates shortcomings of current clinical practices. Arterial base deficit was continuously monitored during 11 clinical resuscitations of patients suffering burn shock using a Paratrend monitor. Separately, in a 30% TBSA rat burn model (N = 70), three Paratrend monitors simultaneously recorded arterial blood gas and tissue pCO2 of the burn wound and colonic mucosa during resuscitation at 0, 2, 4, 6, and 8 ml/kg/%TBSA. Paratrend data were analyzed in conjunction with previously reported laser Doppler images of actual burn wound capillary perfusion. With current clinical therapy, continuous monitoring of arterial base deficit revealed repetitive cycles of resolution/worsening/resolution during burn shock resuscitation. In the rat model, tissue pCO2 in both burn wounds and splanchnic circulation differed depending on the rate of fluid resuscitation (P <.01 between sham and 0 ml/kg/%TBSA and between 2 ml/kg/%TBSA and 4 ml/kg/%TBSA). Burn wound pCO2 values correlated well with laser Doppler determination of actual capillary perfusion (rho = -.48, P <.01). The following conclusions were reached: 1). Gratuitous and repetitive ischemia-reperfusion-ischemia cycles plague current clinical therapy as demonstrated by numerous "false starts" in the resolution of arterial base deficit; 2). in a rat model, real-time monitoring of burn wound and splanchnic pCO2 demonstrate a dose-response relationship with rate of fluid administration; and 3). burn wound and splanchnic pCO2 are highly correlated with direct measurement of burn wound capillary perfusion by laser Doppler imager. Either technique can serve as a resuscitation endpoint for real-time feedback-controlled ultraprecise resuscitation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.