Correlation of cord blood pH, base excess, and lactate concentration measured with a portable device for identifying fetal acidosis.
- Lyne Labrecque, Mathieu Provençal, Aurore Caqueret, Bi Lan Wo, Emmanuel Bujold, François Larivière, and Marie-Josée Bédard.
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC.
- J Obstet Gynaecol Can. 2014 Jul 1;36(7):598-604.
ObjectiveTo determine the effectiveness of portable lactate analyzers in identifying fetal acidosis by correlating arterial and venous lactate values from umbilical cord blood with lactate, pH, and base excess measurements from central laboratory analyzers.MethodsWe performed a prospective study using arterial and venous cord blood from 52 women with a singleton fetus delivered at term. We evaluated the correlation between the cord blood lactate concentration measured using two of the same portable devices (Lactate Plus, Nova Biomedical) with the result from a central laboratory analyzer. Analyses of the correlation between arterial lactate concentration measured on the portable device with arterial pH and base excess were then performed.ResultsWe observed a median arterial pH of 7.24 (range 7.05 to 7.35) and a median arterial lactate concentration of 3.7 mmol/L (range 1.7 to 8.8 mmol/L). An excellent correlation was observed between lactate concentrations measured by the two portable devices (arterial R² = 0.98 and venous R² = 0.98), and between the portable device and the central laboratory analyzer (arterial R² = 0.94 and venous R² = 0.95). In our population, the optimal cut-offs to predict a pH < 7.20 or a base excess > -8.0 mmol/L were a lactate concentration of 4.9 mmol/L and 5.3 mmol/L, respectively, according to receiver operator characteristic analysis. With a lactate concentration > 4.9 mmol/L, the portable device had a sensitivity of 82% and a specificity of 90% to identify samples with an arterial pH < 7.20.ConclusionCord blood lactate concentration measured with a portable device is a good predictor of cord blood base excess and pH. Future studies should be designed to correlate scalp blood lactate measurements with clinical outcomes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.