• J. Cardiothorac. Vasc. Anesth. · Oct 2002

    Differences in arterial and venous thromboelastography parameters: potential roles of shear stress and oxygen content.

    • Robert J Frumento, Andrew L Hirsh, Michael K Parides, and Elliott Bennett-Guerrero.
    • Department of Anesthesiology, Columbia University College of Physicians and Surgeons, Columbia University, New York, NY 10032-3784, USA. rf356@columbia.edu
    • J. Cardiothorac. Vasc. Anesth. 2002 Oct 1;16(5):551-4.

    ObjectiveTo investigate potential mechanisms for the differences in thromboelastography variables observed between arterial blood samples and venous blood samples.DesignProspective cohort study.SettingUniversity hospital.ParticipantsPatients undergoing cardiac surgery (n = 33).InterventionsAfter the withdrawal of 10 mL of discarded blood (>3 deadspace volumes), 3 blood samples were withdrawn simultaneously from the central venous port of the pulmonary artery catheter (CVP), the radial arterial catheter (ART), and the side port of the 9F sheath introducer (SI).Measurements And Main ResultsThromboelastography was done simultaneously on each sample. All thromboelastography analyses were performed with 1% celite and heparinase according to the manufacturer's guidelines. A total of 80 ART, SI, and CVP comparisons were obtained. Mean hematocrit values were not different between sampling sites (27 +/- 4 v 27 +/- 4 v 27 +/- 3). Thromboelastography R time values (mean +/- SD) were CVP, 8 +/- 3; ART, 10 +/- 3; and SI, 13 +/- 5 (p = 0.004). Thromboelastography maximal amplitude (MA) values (mean +/- SD) were CVP, 60.4 +/- 11.7; ART, 56.2 +/- 11.4; and SI, 50.5 +/- 13.2 (p = 0.008). Calculated maximal shear stresses were CVP, 48 dyne/cm(2); ART, 36 dyne/cm(2); and SI, 0.3 dyne/cm(2). Blood samples obtained from the CVP (highest shear stress) resulted in faster (shorter R) and stronger (larger MA) coagulation compared with the arterial site (intermediate shear stress) and sheath introducer (lowest shear stress).ConclusionThese data show that differences exist in thromboelastography values between arterial and venous blood samples and, more importantly, show that the differences observed are not related to differences in oxygen content. These differences seem to be related to differences in catheter lumen diameter and, presumably, shear forces.Copyright 2002, Elsevier Science (USA). All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.