• J Clin Monit · Mar 1996

    End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error.

    • R H Friesen and M Alswang.
    • Department of Anesthesiology and Pediatrics (Critical Care), Children's Hospital, Denver, Colorado 80218, USA.
    • J Clin Monit. 1996 Mar 1;12(2):155-9.

    ObjectiveTo assess the correlation and accuracy of end-tidal PCO2 (PetCO2) sampled via nasal cannulae in pediatric patients by comparison to the criterion standard PaCO2, and to identify sources of error during PetCO2 monitoring via nasal cannulae.MethodsPetCO2 was monitored continuously by sampling end-tidal gas through nasal cannulae that had been designed and manufactured for this purpose in spontaneously breathing children undergoing conscious or deep sedation during either cardiac catheterization (n = 43) or critical care (n = 54). When both the capnographic wave form and the PetCO2 value had been stable for at least 10 minutes, the PetCO2 value was recorded while blood was drawn from an indwelling arterial line for PaCO2 measurement. The effects of age, weight, respiratory rate, oxygen delivery system, airway obstruction, mouth breathing, and cyanotic heart disease were evaluated by linear regression analysis and calculation of absolute bias (PaCO2-PetCO2).ResultsMouth breathing, airway obstruction, oxygen delivery through the ipsilateral nasal cannula, and cyanotic heart disease adversely affected accuracy. In patients without those factors, PetCO2 correlated well with PaCO2 (R2 = 0.994), and absolute bias was 3.0 +/- 1.8 mmHg.ConclusionsSeveral factors-some controllable and all recognizable-affect the accuracy of PetCO2 monitored via nasal cannulae in pediatric patients. When these factors are not present, PetCO2 correlates well with PaCO2 and appears to be a useful monitor of ventilatory status during conscious or deep sedation.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…