• Acta Anaesthesiol Scand · Mar 2014

    The quality of manual chest compressions during transport - effect of the mattress assessed by dual accelerometers.

    • H Hellevuo, M Sainio, H Huhtala, K T Olkkola, J Tenhunen, and S Hoppu.
    • School of Medicine, University of Tampere, Finland; Department of Intensive Care Medicine, Critical Care Medicine Research Group, Tampere University Hospital and University of Tampere, Tampere, Finland.
    • Acta Anaesthesiol Scand. 2014 Mar 1;58(3):323-8.

    BackgroundThe quality of cardiopulmonary resuscitation (CPR) has an impact on survival. The quality may be impaired if the patient needs to be transported to the hospital with ongoing CPR. The aim of this study was to analyse whether the quality of CPR can be improved during transportation by using real-time audiovisual feedback. In addition, we sought to evaluate the real compression depths taking into account the mattress and stretcher effect.MethodsParamedics (n = 24) performed standard CPR on a Resusci Anne Mannequin in a moving ambulance. Participants were instructed to perform CPR according to European Resuscitation Council Resuscitation guidelines 2010. Each pair acted as their own controls performing CPR first without and then with the feedback device. Compression depth, rate and no-flow fraction and also the mattress effect were recorded by using dual accelerometers by two Philips, HeartStart MRx Q-CPR defibrillators.ResultsIn the feedback phase, the mean compression depth increased from 51 (10) to 56 (5) mm (P < 0.001), and the percentage of compression fractions with adequate depth was 60% vs. 89% (P < 0.001). However, taking account of the mattress effect, the real depth was only 41 (8) vs. 44 (5) mm without and with feedback, respectively (P < 0.001). The values for compression rate did not differ.ConclusionsCPR quality was good during transportation in general. However, the results suggest that the feedback system improves CPR quality. Dual accelerometer measurements show, on the other hand, that the mattress effect may be a clinically relevant impediment to high quality CPR.© 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…