• Minerva anestesiologica · Mar 2014

    Observational Study

    Validation of cardiac output studies from the Mostcare compared to a pulmonary artery catheter in septic patients.

    • S Gopal, T Do, J S Pooni, and G Martinelli.
    • Critical Care Services, Heart and Lung Centre, New Cross Hospital, Wolverhampton, UK - shameer.gopal@nhs.net.
    • Minerva Anestesiol. 2014 Mar 1;80(3):314-23.

    BackgroundThe Mostcare monitor is a non-invasive cardiac output monitor. It has been well validated in cardiac surgical patients but there is limited evidence on its use in patients with severe sepsis and septic shock.MethodsThe study included the first 22 consecutive patients with severe sepsis and septic shock in whom the floatation of a pulmonary artery catheter was deemed necessary to guide clinical management. Cardiac output measurements including cardiac output, cardiac index and stroke volume were simultaneously calculated and recorded from a thermodilution pulmonary artery catheter and from the Mostcare monitor respectively. The two methods of measuring cardiac output were compared by Bland-Altman statistics and linear regression analysis. A percentage error of less than 30% was defined as acceptable for this study.ResultsBland-Altman analysis for cardiac output showed a Bias of 0.31 L.min-1, precision (=SD) of 1.97 L.min-1 and a percentage error of 62.54%. For Cardiac Index the bias was 0.21 L.min-1.m-2, precision of 1.10 L.min-1.m-2 and a percentage error of 64%. For stroke volume the bias was 5 mL, precision of 24.46 mL and percentage error of 70.21%. Linear regression produced a correlation coefficient r2 for cardiac output, cardiac index, and stroke volume, of 0.403, 0.306, and 0.3 respectively.ConclusionCompared to thermodilution cardiac output, cardiac output studies obtained from the Mostcare monitor have an unacceptably high error rate. The Mostcare monitor demonstrated to be an unreliable monitoring device to measure cardiac output in patients with severe sepsis and septic shock on an intensive care unit.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…