- Tim-Gerald Kampmeier, Roman-Patrik Lukas, Caroline Steffler, Cristina Sauerland, Thomas P Weber, Hugo Van Aken, and Andreas Bohn.
- Department of Anaesthesiology, Intensive Care and Pain Medicine, University Hospital Muenster, Germany.
- Resuscitation. 2014 Apr 1;85(4):503-8.
AimsCardiopulmonary resuscitation is one of the most vital therapeutic options for patients with cardiac arrest. Sufficient chest compression depth turned out to be of utmost importance to increase the likelihood of a return of spontaneous circulation. Furthermore, the use of real-time feedback-systems for resuscitation is associated with improvement of compression quality. The European Resuscitation Council changed their recommendation about minimal compression depth from 2005 (40 mm) to 2010 (50 mm). The aim of the present study was to determine whether this recommendation of the new guidelines was implemented successfully in an emergency medical service using a real-time feedback-system and to what extend a guideline-based CPR training leads to a "change in behaviour" of rescuers, respectively.Methods And ResultsThe electronic resuscitation data of 294 patients were analyzed retrospectively within two observational periods regarding fulfilment of the corresponding chest compression guideline requirements: ERC 2005 (40 mm) 01.07.2009-30.06.2010 (n=145) and ERC 2010 (50mm) 01.07.2011-30.06.2012 (n=149). The mean compression depth during the first period was 47.1mm (SD 11.1) versus 49.6 mm (SD 12.0) within the second period (p<0.001). With respect to the corresponding ERC Guidelines 2005 and 2010, the proportion of chest compressions reaching the minimal depth decreased (73.9% vs. 49.1%) (p<0.001). There was no correlation between compression depth and patient age, sex or duration of resuscitation.ConclusionsThe present study was able to show a significant increase in chest compression depth after implementation of the new ERC guidelines. Even by using a real-time feedback system we failed to sustain chest compression quality at the new level as set by ERC Guidelines 2010. In consequence, the usefulness of a fixed chest compression depth should be content of further investigations.Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.