• Artificial organs · Sep 2013

    Comparative Study

    Comparison of hemolysis between CentriMag and RotaFlow rotary blood pumps during extracorporeal membrane oxygenation.

    • David A Palanzo, Aly El-Banayosy, Edward Stephenson, Christoph Brehm, Allen Kunselman, and Walter E Pae.
    • Heart and Vascular Institute, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA.
    • Artif Organs. 2013 Sep 1;37(9):E162-6.

    AbstractThe purpose of this investigation was to compare the hemolysis levels for patients on extracorporeal membrane oxygenation (ECMO) incorporating two different rotary blood pumps (CentriMag [CMAG] and RotaFlow [RF]) in identical circuits otherwise. The difference between the two pumps is the cost. One is 20-30 times less expensive than the other. A retrospective analysis of all patients placed on ECMO from June 2008 through May 2012 was done to evaluate hemolysis. Daily plasma hemoglobin (pHb), lactate dehydrogenase (LDH), and lactate levels were collected on all patients. Values were compared between those patients who received a CMAG and those who received an RF. Patients had to be on ECMO for more than 2 days to be included in the study. Linear mixed effects models were fit to the data to assess differences over time for each continuous outcome. Forty patients were placed on ECMO incorporating CMAG, whereas 40 patients received an RF. There were no significant statistical differences between CMAG and RF groups when comparing days on support (8.7 ± 5.0; 8.4 ± 5.7), age (44.8 ± 18.3; 46.1 ± 16.0), body surface area (2.03 ± 0.36; 1.96 ± 0.31), gender (male: 58%, female: 42%; male: 55%, female: 45%), etiology, type of support (veno-arterial [VA)]: 78%, veno-venous [VV)]: 22%; VA: 82%, VV: 18%) and pre-ECMO LDH levels (4004.0 ± 3583.2; 3603.7 ± 3354.1). There were also no significant differences between the CMAG and RF groups when comparing the mean values for daily pHb levels (5.7 ± 3.6; 5.7 ± 4.2), lactate levels (2.8 ± 1.9; 3.0 ± 2.1), and LDH levels (2656.3 ± 1606.8; 2688.6 ± 1726.1) or daily lactate, LDH, and pHb levels for the first 10 days of support. From our investigation, there is no difference between the CMAG and the RF blood pumps in regard to the creation of hemolysis during ECMO. The difference in cost of the devices does not correlate with the performance and outcomes.© 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.