• J Trauma · Oct 2001

    Role of duodenography in the diagnosis of blunt duodenal injuries.

    • C H Timaran, B J Daley, and B L Enderson.
    • Department of Surgery, University of Tennessee Medical Center, Knoxville, Tennessee 37920-6999, USA.
    • J Trauma. 2001 Oct 1;51(4):648-51.

    BackgroundThe differentiation of duodenal perforation from duodenal hematoma is not always possible with computed tomography (CT). Our diagnostic guideline has included duodenography to investigate CT findings of periduodenal fluid or wall thickening. However, the utility of duodenography as a diagnostic study in blunt abdominal trauma is not defined. We evaluated duodenography as a diagnostic test in patients with suspected blunt duodenal injuries (BDIs).MethodsDuring a 10-year period, 96 patients out of 25,608 trauma admissions had CT findings of possible BDI and underwent duodenography. Demographic and clinical data, diagnostic methods, and management were derived from prospectively collected data. CT and duodenography studies were reviewed and correlated with surgical findings and outcome. All CT scans were obtained with intravenous contrast; oral contrast was used in 32 patients. Duodenography was analyzed using the 2 x 2 method and Bayes theorem.ResultsIndications for duodenography included periduodenal fluid without extravasation (76%), abnormal duodenal wall thickening (16%), and retroperitoneal extraluminal gas (5%). Eighty-six duodenography studies were reported as normal, six were consistent with hematoma, one was indeterminate, and only three revealed extravasation. Two of these three patients with duodenal perforation had retroperitoneal extraluminal air. Only one patient underwent exploration on the basis of duodenography. No blunt duodenal perforation was diagnosed by CT. Overall, duodenography had sensitivity of 54% and specificity of 98%. For BDIs requiring repair, duodenography sensitivity was only 25%; the false-negative rate was also 25%. Retroperitoneal extraluminal air was a useful sign of duodenal perforation, occurring in two of three patients with BDI and only in one without BDI (p < 0.001).ConclusionDuodenography has a low sensitivity in patients with suspected BDI by CT findings and is of minimal utility in diagnostic evaluation. Retroperitoneal extraluminal air seen on CT is an important sign of BDI requiring surgical repair.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…