• Emerg Med Australas · Aug 2004

    Comparative Study Clinical Trial

    Does potassium concentration measured on blood gas analysis agree with serum potassium in patients with diabetic ketoacidosis?

    • Phyllis Fu, George Douros, and Anne-Maree Kelly.
    • Department of Emergency Medicine, Western Hospital, Victoria, Australia.
    • Emerg Med Australas. 2004 Aug 1;16(4):280-3.

    ObjectiveThe aims of this study were to define the maximum clinically acceptable difference between potassium concentrations on different samples and to determine the degree of agreement between potassium concentration measured on blood gas analysis and serum for patients with diabetic ketoacidosis (DKA).MethodsThis project comprised two sub studies. In the first, 15 emergency physicians, intensivists and endocrinologists were surveyed and asked to mark on a line with markings at 0.5 mmol/L intervals, the maximum clinically acceptable differences (both above and below the 'true' value) between potassium concentration measured on different samples. The maximum clinically acceptable difference was calculated as the median of responses. The second study was a retrospective agreement study. Patients with an ED diagnosis of DKA were identified from a computer database. They were eligible for inclusion if they had both blood gas analysis including potassium concentration and serum potassium concentration and pH was less than 7.3. Data collected included potassium concentration on serum and blood gas samples, pH, serum glucose concentration and time of sample collections. Data were analysed using bias plot and Spearman correlation analyses.ResultsThe maximum clinically acceptable difference was defined as 0.5 mmol/L for both over and underestimation of potassium concentration. Fifty patients were studied with a median pH of 7.17 and median serum glucose of 29.5 mmol/L. Difference in potassium concentration between samples ranged from -0.9-2.9 mmol/L. 80% of sample pairs had a difference within the maximum clinically acceptable difference defined previously. The magnitude of difference between samples correlated with serum glucose (P = 0.0033, coefficient 0.41) but not with pH.ConclusionThis study suggests that potassium concentration derived from blood gas analysis may not be an acceptable substitute for serum potassium concentration in patients with diabetic ketoacidosis, particularly at higher serum glucose concentrations.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…