- Erik Alonso, Digna González-Otero, Elisabete Aramendi, Sofía Ruiz de Gauna, Jesús Ruiz, Unai Ayala, James K Russell, and Mohamud Daya.
- Communications Engineering Department, University of the Basque Country UPV/EHU, Alameda Urquijo S/N, 48013 Bilbao, Spain. Electronic address: erik_alonso@ehu.es.
- Resuscitation. 2014 May 1;85(5):637-43.
AimTo analyze the relationship between the depth of the chest compressions and the fluctuation caused in the thoracic impedance (TI) signal in out-of-hospital cardiac arrest (OHCA). The ultimate goal was to evaluate whether it is possible to identify compressions with inadequate depth using information of the TI waveform.Methods60 OHCA episodes were extracted, one per patient, containing both compression depth (CD) and TI signals. Every 5s the mean value of the maxima of the CD, Dmax, and three features characterizing the fluctuations caused by the compressions in the TI waveform (peak-to-peak amplitude, area and curve length) were computed. The linear relationship between Dmax and the TI features was tested using Pearson correlation coefficient (r) and univariate linear regression for the whole population, for each patient independently, and for series of compressions provided by a single rescuer. The power of the three TI features to classify each 5s-epoch as shallow/non-shallow was evaluated in terms of area under the curve, sensitivity and specificity.ResultsThe r was 0.34, 0.36 and 0.37 for peak-to-peak amplitude, area and curve length respectively when the whole population was analyzed. Within patients the median r was 0.40, 0.43 and 0.47, respectively. The analysis of the series of compressions yielded a median r of 0.81 between Dmax and the peak-to-peak amplitude, but it decreased to 0.47 when all the series were considered jointly. The classifier based on the TI features showed 90.0%/37.1% and 86.2%/43.5% sensitivity/specificity values, and an area under the curve of 0.75 and 0.71 for the training and test set respectively.ConclusionLow linearity between CD and TI was noted in OHCA episodes involving multiple rescuers. Our findings suggest that TI is unreliable as a predictor of Dmax and inaccurate in detecting shallow compressions.Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.