• Critical care medicine · Feb 1994

    Variability of cardiac output over time in medical intensive care unit patients.

    • S A Sasse, P A Chen, R B Berry, C S Sassoon, and C K Mahutte.
    • Department of Medicine, Long Beach Veterans Affairs Medical Center, CA.
    • Crit. Care Med. 1994 Feb 1;22(2):225-32.

    ObjectivesTo determine the amount of spontaneous variability of cardiac output over time in critically ill patients, and to determine the effect of mechanical ventilation on cardiac output variability over time.DesignCase series.SettingMedical intensive care unit in a Veterans Affairs Medical Center.PatientsTwenty-two patients with indwelling pulmonary artery flotation catheters were studied. Two patients were studied twice.InterventionsDuring a 1-hr time period in which no interventions were required or made, thermodilution cardiac output was determined at baseline and then every 15 mins for 1 hr. At each time point, five individual cardiac output measurements were made and a mean was computed. The covariables of heart rate, respiration rate, mean arterial pressure, mean pulmonary arterial pressure, pulmonary artery occlusion pressure, and temperature were also recorded at each time point.Measurements And Main ResultsThe variability of the five cardiac output measurements made at each time point was expressed by calculating for each patient a coefficient of variation of the measurements. The overall mean coefficient of variation of the measurements was 5.8%. The variability of the cardiac output measurements over time was expressed by calculating for each patient a coefficient of variation over time. The overall mean coefficient of variation over time was 7.7%. A subgroup of 15 "covariable stable" patients (defined as those patients with covariables within +/- 5% of the mean covariable values during the hour) had a mean coefficient of variation over time of 6.4%, whereas "covariable unstable" patients (with > +/- 5% changes in any covariable) had a mean coefficient of variation over time of 9.9% (p < .05). Patients breathing spontaneously had a mean coefficient of variation over time of 10.1%, whereas mechanically ventilated patients had a mean coefficient of variation over time of 6.3% (p < .05).ConclusionsThe spontaneous variability of cardiac output should be considered when interpreting two cardiac output determinations made at separate times. Due to spontaneous variability alone, a patient with a baseline cardiac output of 10.0 L/min would be expected (95% confidence interval) to have a cardiac output range of 9.2 to 10.8 L/min if covariables were stable, and a range of at least 8.8 to 11.2 L/min if covariables were unstable. Patients who were mechanically ventilated displayed less variability than patients who were breathing spontaneously.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.