• J Med Assoc Thai · Jun 2004

    Randomized Controlled Trial Clinical Trial

    Maternal satisfaction to epidural and spinal anesthesia for cesarean section.

    • Wacharin Sindhvananda, Ruenreong Leelanukrom, Oraluxna Rodanant, and Pin Sriprajittichai.
    • Department of Anesthesiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
    • J Med Assoc Thai. 2004 Jun 1;87(6):628-35.

    Background And ObjectiveThe differences between epidural (EA) and spinal (SA) anesthesia that can affect maternal satisfaction are the procedures, quality of anesthesia and postoperative events. Dominantly, postoperative events such as postdural puncture headache, pruritus and nausea or vomiting after spinal anesthesia are claimed to be its disadvantages. However, maternal satisfactory perception to theses two techniques has not been revealed. The authors' purpose was to compare maternal satisfaction regarding the techniques and their outcomes between EA and SA by the developed valid and reliable tool.Material And MethodPatients were randomly classified into two groups: epidural (Group E, n=56) and spinal (Group S, n = 58). Epidural and spinal anesthesia were administered with bupivacaine, 20 mL 0.5% with 1:200,000 epinephrine combined with two doses of 5 mg morphine and hyperbaric bupivacaine 2.2-2.4 mL 0.5% combined with 0.2 mg morphine respectively. Guidelines for treatment of intraoperative and postoperative events, which might be the confounding factors, were set up. Maternal satisfaction was evaluated by the 11-item, qualified, self-administered questionnaire comprised of 4 common factors. The score of 0-10 Visual analog scale was used to access the degree of satisfaction. Trained personnel performed data collections in the post-anesthesia care unit and ward. The means of the factor and total satisfaction scores were compared between the two groups by Mann Whitney U test. A p-value < 0.05 considered significant.ResultsThere was no statistical difference in the factor scores between the two groups. The total satisfactory score was 89.48 +/- 9.31 and 90.03 +/- 11.26 in Group E and S respectively. No statistical difference of the total satisfaction score was detected.ConclusionThere was no difference in maternal satisfaction regarding to the techniques and the outcomes between EA and SA.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…