• Heart Rhythm · Oct 2005

    Tailored echocardiographic interventricular delay programming further optimizes left ventricular performance after cardiac resynchronization therapy.

    • Marc Vanderheyden, Tine De Backer, Maximo Rivero-Ayerza, Peter Geelen, Jozef Bartunek, Sofie Verstreken, Mark De Zutter, and Marc Goethals.
    • Cardiovascular Center, Onze Lieve Vrouw Ziekenhuis, Aalst, Belgium. marc.vanderheyden@olvz-aalst.be
    • Heart Rhythm. 2005 Oct 1;2(10):1066-72.

    BackgroundThe aim of cardiac resynchronization therapy is correction of left ventricular (LV) dyssynchrony. However, little is known about the optimal timing of LV and right ventricular (RV) stimulation.ObjectivesThe purpose of this study was to evaluate the acute hemodynamic effects of biventricular pacing, using a range of interventricular delays in patients with advanced heart failure.MethodsTwenty patients with dilated ischemic (n = 12) and idiopathic (n = 8) cardiomyopathy (age 66 +/- 6 years, New York Heart Association class III-IV, LV end-diastolic diameter >55 mm, ejection fraction 22% +/- 18%, and QRS 200 +/- 32 ms) were implanted with a biventricular resynchronization device with sequential RV and LV timing (VV) capabilities. Tissue Doppler echocardiographic parameters were measured during sinus rhythm before implantation and following an optimal AV interval with both simultaneous and sequential biventricular pacing. The interventricular interval was modified by advancing the LV stimulus (LV first) or RV stimulus (RV first) up to 60 ms. For each stimulation protocol, standard echocardiographic Doppler and tissue Doppler imaging (TDI) echo were used to measure the LV outflow tract velocity-time integral, LV filling time, intraventricular delay, and interventricular delay.ResultsThe highest velocity-time integral was found in 12 patients with LV first stimulation, 5 patients with RV first stimulation, and 3 patients with simultaneous biventricular activation. Compared with simultaneous biventricular pacing, the optimized sequential biventricular pacing significantly increased the velocity-time integral (P <.001) and LV filling time (P = .001) and decreased interventricular delay (P = .013) and intraventricular delay (P = .010). The optimal VV interval could not be predicted by any clinical nor echocardiographic parameter. At 6-month follow-up, the incidence of nonresponders was 10%.ConclusionOptimal timing of the interventricular interval results in prolongation of the LV filling time, reduction of interventricular asynchrony, and an increase in stroke volume. In patients with advanced heart failure undergoing cardiac resynchronization therapy, LV hemodynamics may be further improved by optimizing LV-RV delay.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…