• Braz J Anesthesiol · May 2015

    Randomized Controlled Trial

    Minimum effective concentration of bupivacaine for axillary brachial plexus block guided by ultrasound.

    • Alexandre Takeda, Leonardo Henrique Cunha Ferraro, André Hosoi Rezende, Eduardo Jun Sadatsune, Falcão Luiz Fernando dos Reis LF Department of Anesthesiology, Pain and Intensive Care, Escola Paulista de Medicina, Universidade Federal de São Paulo (UNIFESP), São Paul, and Maria Angela Tardelli.
    • Department of Anesthesiology, Pain and Intensive Care, Escola Paulista de Medicina, Universidade Federal de São Paulo (UNIFESP), São Paulo, SP, Brazil.
    • Braz J Anesthesiol. 2015 May 1; 65 (3): 163-9.

    IntroductionThe use of ultrasound in regional anesthesia allows reducing the dose of local anesthetic used for peripheral nerve block. The present study was performed to determine the minimum effective concentration (MEC90) of bupivacaine for axillary brachial plexus block.MethodsPatients undergoing hand surgery were recruited. To estimate the MEC90, a sequential up-down biased coin method of allocation was used. The bupivacaine dose was 5 mL for each nerve (radial, ulnar, median, and musculocutaneous). The initial concentration was 0.35%. This concentration was changed by 0.05% depending on the previous block; a blockade failure resulted in increased concentration for the next patient; in case of success, the next patient could receive or reduction (0.1 probability) or the same concentration (0.9 probability). Surgical anesthesia was defined as driving force ≤ 2 according to the modified Bromage scale, lack of thermal sensitivity and response to pinprick. Postoperative analgesia was assessed in the recovery room with numeric pain scale and the amount of drugs used within 4h after the blockade.ResultsMEC90 was 0.241% [R(2): 0.978, confidence interval: 0.20-0.34%]. No patient, with successful block, reported pain after 4h.ConclusionThis study demonstrated that ultrasound guided axillary brachial plexus block can be performed with the use of low concentration of local anesthetics, increasing the safety of the procedure. Further studies should be conducted to assess blockade duration at low concentrations.Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.