• J Trauma · Aug 2003

    Comparative Study

    Blunt chest trauma victims: role of intravascular ultrasound and transesophageal echocardiography in cases of abnormal thoracic aortogram.

    • Nilesh H Patel, David Hahn, and Keith A Comess.
    • Department of Radiology, Harborview Medical Center, Seattle, Washington, USA. nhpatel@cvir.com
    • J Trauma. 2003 Aug 1;55(2):330-7.

    PurposeThe objective of our study was to use transesophageal echocardiography (TEE) and intravascular ultrasonography (IVUS) to evaluate their role in interrogating abnormal or equivocal findings seen on thoracic aortography performed on blunt chest trauma patients.MethodsA prospective, nonblinded, observational, institutional review board-approved study of IVUS and TEE was conducted in acute blunt chest trauma victims with abnormal findings on thoracic aortograms. IVUS was performed with a 20-MHz catheter and TEE was performed with an omniplane probe.ResultsAbnormal aortographic findings were present in 10 men and 4 women (mean age, 40.5 years). All 14 patients were evaluated with IVUS and 13 with TEE. TEE was not performed on one patient because of time constraints. By IVUS, there were 11 true-positives, 2 true-negatives, and 1 equivocal (considered as false-negative), resulting in 91.7% sensitivity and 100% specificity. In the equivocal case, an intimal flap was missed by IVUS and by TEE, but was present at surgery. By TEE, there were six true-positives, two true-negatives, one false-positive, and four false-negatives, resulting in 60% sensitivity and 66.7% specificity. In the false-positive case, an avulsed intercostal artery without an intimal flap was found at surgery. The remaining three false-negative cases were a missed intimal flap, a missed intramural hematoma, and a missed intimal flap obscured by a mural hematoma. In our study, both IVUS and TEE were found to be diagnostic in the four equivocal aortograms. Three of the equivocal results were cases read as a prominent ductus diverticulum versus a pseudoaneurysm. Two were confirmed to be false lumen/pseudoaneurysm by both IVUS and TEE, whereas the other was confirmed to be a prominent ductus diverticulum by both of these modalities. In the fourth equivocal case, thoracic aortography showed an abnormal contour but no intimal flap located along the lesser curvature of the aorta at the junction of the arch and isthmus. No abnormalities were found by IVUS or TEE. This patient was followed clinically. A follow-up thoracic aortogram obtained 1 year later showed no aortic injury.ConclusionWhen thoracic aortography yields an abnormal and especially equivocal findings, both IVUS and TEE are helpful in further sorting this out rather than subjecting the patient to a potentially unnecessary thoracotomy. In cases of aortic injury suspected at the lesser curvature of the arch-isthmic junction, TEE allowed better delineation because of multiplane imaging capability.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…