Background And ObjectiveThe measurement of breathing pattern in patients with chronic obstructive pulmonary disease (COPD) by electrical impedance tomography (EIT) requires the use of a mathematical calibration model incorporating not only anthropometric characteristics (previously evaluated in healthy individuals) but probably functional alterations associated with COPD as well. The aim of this study was to analyze the association between EIT measurements and spirometry parameters, static lung volumes, and carbon monoxide diffusing capacity (DLCO) in a group of male patients to develop a calibration equation for converting EIT signals into volume signals.Materials And MethodsWe measured forced vital capacity (FVC), forced expiratory volume in 1 second (FEV(1)), FEV(1)/FVC, residual volume, total lung capacity, DLCO, carbon monoxide transfer coefficient (KCO) and standard anthropometric parameters in 28 patients with a FEV(1)/FVC ratio of <70%. We then compared tidal volume measurements from a previously validated EIT unit and a standard pneumotachometer.ResultsThe mean (SD) lung function results were FVC, 72 (16%); FEV(1), 43% (14%); FEV(1)/FVC, 42% (9%); residual volume, 161% (44%); total lung capacity, 112% (17%); DLCO, 58% (17%); and KCO, 75% (25%). Mean (SD) tidal volumes measured by the pneumotachometer and the EIT unit were 0.697 (0.181)L and 0.515 (0.223)L, respectively (P<.001). Significant associations were found between EIT measurements and CO transfer parameters. The mathematical model developed to adjust for the differences between the 2 measurements (R(2)=0.568; P<.001) was compensation factor=1.81# - 0.82# height (m)# -0.004 x KCO (%).ConclusionsThe measurement of breathing pattern by EIT in patients with COPD requires the use of a previously calculated calibration equation that incorporates not only individual anthropometric characteristics but gas exchange parameters as well.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.