You need to sign in or sign up before continuing.


  • Rev Mal Respir · Jan 1992

    Multicenter Study Clinical Trial

    [The quality of oxygen therapy delivery systems using oxygen-saving valves. A multicenter study. The ANTADIR Medico-Technical Commission].

    • B Segard, J F Muir, J M Bédicam, C Defouilloy, and A Sautegeau.
    • ANTADIR, Paris.
    • Rev Mal Respir. 1992 Jan 1;9(2):197-204.

    AbstractThe saturation of oxygen (SaO2) using oxygen therapy with an oxygen saving system, Optimox (CFPO) or COS 5 (Puritan, Bennett) has been compared to the SaO2 using continuous oxygen therapy. The oxygen output using the oxygen saving system was regulated in such a way as to be equivalent to the oxygen flow without the economiser. Three situations were studied: the day, the night and during effort. Ninety four patients (84 men and 10 women), aged 65.3 +/- 9.7), who were hypoxaemic (SaO2: 84.5 +/- 6.4%) coming from twelve pneumology units were included in the study. The percentage of time spent above SaO2 (T greater than 90) was used to judge the criteria of the efficacy of the oxygen therapy. T greater than 90 without (SSECO) and with the oxygen saving system (AVECO) were compared in each subject. T greater than 90 AVECO was below T greater than 90 SSECO in 52% of patients and was greater in 23% of subjects. The nasal, auditory and respiratory comfort was good whatever the period of examination for more than half of the subjects. In conclusion for an equivalent oxygen flow the addition of an oxygen saving device significantly alters the quality of diurnal and nocturnal oxygen therapy in one patient out of two.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.