• Vasc Health Risk Manag · Jan 2014

    Review Meta Analysis

    Diagnostic accuracy of sensitive or high-sensitive troponin on presentation for myocardial infarction: a meta-analysis and systematic review.

    • Ankur Sethi, Anurag Bajaj, Gurveen Malhotra, Rohit R Arora, and Sandeep Khosla.
    • Department of Medicine, Division of Cardiology, Rosalind Franklin University of Medicine and Science, North Chicago, IL, USA.
    • Vasc Health Risk Manag. 2014 Jan 1;10:435-50.

    BackgroundRecently, high-sensitive troponin (hsTrop) assays consistent with professional societies' recommendations became available. We aimed to summarize the evidence on the diagnostic accuracy of hsTrop on presentation.MethodsWe searched electronic databases for studies evaluating the diagnostic accuracy of hsTrop in suspected acute coronary syndrome (ACS) patients. Random effect meta-analyses and meta-regression were performed. Primary and secondary analyses were restricted to studies using conventional Trop and hsTrop in the reference standard, respectively.ResultsFifteen studies with a total of 8,628 patients met the inclusion criteria for the primary analysis. hsTrop T (Hoffman-La Roche Ltd) and hsTrop I (Siemens) had sensitivities of 0.89 (95% confidence interval [CI]: 0.86-0.91) and 0.90 (95% CI: 0.87-0.92) and specificities of 0.79 (95% CI: 0.77-0.80) and 0.89 (95% CI: 0.87-0.90), respectively. There was no statistically significant difference in the area under the curve between hsTrop (95% CI: 0.920) and conventional Trop (95% CI: 0.929) at the 99th percentile (P=0.62). hsTrop at the level of detection had a sensitivity of 0.97 (95% CI: 0.96-0.98) and a specificity of 0.41 (95% CI: 0.40-0.42). The studies using a cut-off at coefficient of variance <10% as opposed to the 99th percentile for the conventional assay used for diagnosis reported higher diagnostic accuracy (relative diagnostic odds ratio =2.13, P=0.02). Five studies were included in the secondary analysis; hsTrop T (Hoffman-La Roche Ltd) had a sensitivity of 0.91 (95% CI: 0.89-0.93) and a specificity of 0.67 (95% CI: 0.63-0.70). There was significant heterogeneity among the studies.ConclusionhsTrop have excellent diagnostic accuracy for myocardial infarction on presentation, but may not outperform conventional Trop assays. The variation among the studies can be explained, in part, by the cut-off used for conventional Trop assays.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…