Am. J. Physiol. Heart Circ. Physiol. · Jul 2007
Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance.
- Hanan Keren, Daniel Burkhoff, and Pierre Squara.
- Cheetah Medical Limited, Ra'anana, Israel.
- Am. J. Physiol. Heart Circ. Physiol. 2007 Jul 1;293(1):H583-9.
AbstractNoninvasive cardiac output (CO) measurement can be useful in many clinical settings where invasive monitoring is not desired. Bioimpedance (intrabeat measurement of changes in transthoracic voltage amplitude in response to an injected high-frequency current) has been explored for this purpose but is limited in some clinical settings because of inherently low signal-to-noise ratio. Since changes in fluid content also induce changes in thoracic capacitive and inductive properties, we tested whether a noninvasive CO measurement could be obtained through measurement of the relative phase shift of an injected current (i.e., bioreactance). We constructed a prototype device that applies a 75-kHz current and determines the relative phase shift (dPhi/dt) of the recorded transthoracic voltage. CO was related to the product of peak dPhi/dt, heart rate, and ventricular ejection time. The preclinical study was done in nine open-chest pigs put on right heart bypass so that CO could be varied at known values. This was followed by a feasibility study in 27 postoperative patients who had a Swan-Ganz catheter (SGC). The measurements of noninvasive CO measurement and cardiopulmonary bypass pump correlated to each other (r = 0.84) despite the large variation in CO and temperatures. Similarly, in patients, mean CO values were 5.18 and 5.17 l/min as measured by SGC and the noninvasive CO measurement system, respectively, and were highly correlated over the range of values studied (r = 0.90). Preclinical and clinical data demonstrate the feasibility of using blood flow-related phase shifts of transthoracic electric signals to perform noninvasive continuous CO monitoring.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.