• Chest · Dec 1994

    Automatic weaning from mechanical ventilation using an adaptive lung ventilation controller.

    • D M Linton, P D Potgieter, S Davis, A T Fourie, J X Brunner, and T P Laubscher.
    • Department of Medicine, Groote Schuur Hospital, Cape Town, South Africa.
    • Chest. 1994 Dec 1;106(6):1843-50.

    Study ObjectiveTo evaluate a new method of closed-loop mechanical ventilation using an adaptive lung ventilation (ALV) controller in patients with different pathologic causes of respiratory failure at a time when they first met standard weaning criteria.Study DesignProspective, open, selected case study.SettingThe 10-bed, multidisciplinary respiratory intensive care unit at Groote Schuur hospital, which is a teaching unit of the University of Cape Town.PatientsTwenty-seven patients (9 patients in each of 3 groups: normal lungs, parenchymal lung disease, and COPD) who required prolonged mechanical ventilation and who met standard weaning criteria were included. Our institutional committee for ethical research approved the study and informed consent was obtained.InterventionsThe patients were mechanically ventilated and had daily measurements of vital capacity, respiratory rate, and arterial blood gas analysis until they met standard weaning criteria. On the day that each patient met the weaning criteria, a closed loop control algorithm providing ALV was implemented on a modified ventilator (Hamilton AMADEUS) with a PC-based lung function analyzer. After measuring gross alveolar ventilation, patients were placed in ALV and ventilatory and hemodynamic parameters were measured at baseline, 5 min, 30 min, and 2 h. Pertinent parameters measured included airway pressures, pressure support levels, respiratory rates, rapid shallow breathing indices, airway resistance indices, and patient respiratory drive and work indices.Measurements And ResultsIn 22 patients, ALV reduced pressure support to 5 cm H2O and an intermittent mandatory ventilation rate of 4 breaths/min within 30 min, and all but 1 of these patients were successfully extubated within 24 h. In four patients, pressure support was maintained by ALV at a mean level of 14.6 cm H2O +/- for 2 h and these patients were recorded as having failed to wean. There was a measurable difference in an index of airway resistance relative to muscular activity between the successfully weaned and failed wean patients with COPD during the attempted wean by the ALV controller.ConclusionsALV will provide a safe, efficient wean and will respond immediately to inadequate ventilation in patients when standard weaning criteria are met.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.