Comparative Study
Quantifying recirculation in extracorporeal membrane oxygenation: a new technique validated.
- Steven J Lindstrom, Mark T Mennen, Franklin L Rosenfeldt, and Robert F Salamonsen.
- Department of Epidemiology and Preventive Medicine, Monash University, Victoria, Australia. s.lindstrom@alfred.org.au
- Int J Artif Organs. 2009 Dec 1;32(12):857-63.
RationaleThe efficacy of veno-venous extracorporeal membrane oxygenation is limited by the phenomenon of recirculation, which is difficult to quantify. Existing measurement techniques using readily available equipment are unsatisfactory.Objectives1) To compare the accuracy of measurements of recirculation made using equations comparing blood oxygen content or saturation alone at different points in an ex vivo circuit; 2) to validate a new step-change technique for quantifying recirculation in vivo.Methodsanesthetized greyhound dogs cannulated for veno-arterial support were connected to a circuit that allowed the creation of a known level of recirculation ex vivo and blood oxygen content/saturation monitoring. In two dogs, the accuracy of measurements derived from oxygen content and oxygen saturation were compared. The potential of a new technique for measuring recirculation in vivo by comparing the oxygen content of blood sampled during oxygenator bypass to that following a step-change in circuit oxygenation was demonstrated in a veno-venous pilot study and validated in a three-dog veno-arterial study.ResultsMeasurements made using oxygen content versus oxygen saturation showed superior correlation with true recirculation (r(2)=0.87 vs. 0.64, p<0.0001) and less proportional measurement bias (10.3% vs. 49.8%, p=0.0045). Measurements of recirculation made using a step-change in circuit oxygenation and comparing oxygen content as is required for measuring in vivo recirculation overestimated by only 18.6% (95% Cl: 3.9-33.2%) and had excellent correlation with true values (r(2)=0.89).Conclusions1) Measurement of recirculation using oxygen content is superior to that using oxygen saturation alone, which demonstrates significant measurement bias; 2) the novel step-change technique is a sufficiently accurate technique for the measurement of recirculation in animal models.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.