-
J Clin Monit Comput · Jun 2009
Clinical TrialHaemodynamic changes during craniotomy monitored by a bioimpedance plethysmographic noninvasive cardiac output monitor.
- Zulfiqar Ali, G S Umamaheswara Rao, and A Jaganath.
- Department of Neuroanaesthesia, All India Institute of Medical Sciences, New Delhi, India.
- J Clin Monit Comput. 2009 Jun 1;23(3):157-61.
BackgroundProfound cardiovascular changes may occur at various stages during a craniotomy. These changes require a detailed haemodynamic analysis including cardiac output. In the present study, we used a monitor based on electrical bioimpedance method for noninvasive cardiac output measurement.MethodsIn 17 ASA I and II patients undergoing elective craniotomies for supratentorial tumours, the following haemodynamic parameters were measured noninvasively: heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), stroke volume (SV), cardiac output (CO) and systemic vascular resistance (SVR). Haemodynamic changes in response to the following events were studied: (a) induction of anaesthesia with thiopentone, (b) 15 min of air-O(2)-isoflurane anaesthesia, (c) infiltration of the scalp with lidocaine adrenaline mixture, and (d) change of inspired gas mixture to N(2)O-O(2)-isoflurane.ResultsHR increased (P < 0.001) and SV decreased (P < 0.001) while CO remained unchanged, one min after administration of thiopentone. After 15 min of isoflurane anaesthesia, HR increased (P < 0.001) and, SBP (P = 0.02), DBP (P = 0.002) and SV (P = 0.003) decreased significantly without change in CO. Three minutes after infiltration of the scalp with lidocaine-adrenaline mixture, there was an increase in SBP (P = 0.001), DBP (P = 0.007), SV (P = 0.007) and CO (P = 0.001) and a decrease in SVR (P < 0.001). Addition of nitrous oxide (60%) to the inspired gas mixture decreased SBP (P = 0.003) and DBP (P = 0.001) with a trend for decrease in CO (P < 0.1). The changes recorded in the present study conform to those that have been documented earlier by using invasive monitoring.ConclusionBioimpedance plethysmography is a useful noninvasive technique for monitoring and detailed analysis of the rapidly changing systemic haemodynamics during a craniotomy. The device could be useful for investigating important haemodynamic changes in specific neurosurgical settings.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.