    Ventilator-associated pneumonia and frequency of circuit changes.

    • A M Stamm.
    • Department of Medicine, University of Alabama at Birmingham 35294, USA.
    • Am J Infect Control. 1998 Feb 1;26(1):71-3.

    BackgroundThe purpose of this research was to determine whether changing tubing circuits for mechanical ventilation less often than every 48 hours would allow maintenance of acceptably low rates for ventilator-associated pneumonia.MethodsA computer search of the MEDLINE database from 1986 through 1996 was performed, and abstracts for 1992 through 1996 from the annual meetings of the Association for Professionals in Infection Control and Epidemiology and the Society for Healthcare Epidemiology of America were examined.ResultsEight studies indicate that the interval between ventilator tubing circuit changes can be extended to 7 days without increasing the rate of ventilator-associated pneumonia. Furthermore, the rate can be maintained at or below 10 pneumonias per 1000 ventilator-days, the approximate median of the National Nosocomial Infections Surveillance System. There is very little evidence to suggest that these circuits can safely be changed at longer intervals.ConclusionsThe weight of the evidence indicates that breathing circuits should be changed every 7 days. This practice of routine changes should be abandoned only if additional studies demonstrate that prolonged use of the same breathing circuit is associated with low rates of ventilator-associated pneumonia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.