Anesthesia and analgesia · May 2012
A life cycle assessment of reusable and single-use central venous catheter insertion kits.
- Forbes McGain, Scott McAlister, Andrew McGavin, and David Story.
- Department of Anaesthesia, Western Health, Melbourne, Victoria, Australia. forbes.mcgain@wh.org.au
- Anesth. Analg.. 2012 May 1;114(5):1073-80.
BackgroundFor most items used in operating rooms, it is unclear whether reusable items are environmentally and financially advantageous in comparison with single-use variants. We examined the life cycles of reusable and single-use central venous catheter kits used to aid the insertion of single-use, central venous catheters in operating rooms. We did not examine the actual disposable catheter sets themselves. We assessed the entire financial and environmental costs for the kits, including the influence of the energy source used for sterilization.MethodsFor the reusable central venous catheter kit, we performed a "time-in-motion" study to determine the labor costs and measured the energy and water consumption for cleaning and sterilization at Western Health, Melbourne, Australia. For the majority of the inputs for the single-use kit, we relied upon industry and inventory-sourced databases. We modeled the life cycles of the reusable and single-use central venous catheter kits with Monte Carlo analysis.ResultsInclusive of labor, the reusable central venous catheter insertion kits cost $6.35 Australian ($A) (95% confidence interval [CI], $A5.89 to $A6.86), and the single-use kits cost $A8.65. For the reusable kit, CO(2) emissions were 1211 g (95% CI, 1099 to 1323 g) and for the single-use kit 407 g (95% CI, 379 to 442 g). Water use was 27.7 L (95% CI, 27.0 to 28.6 l) for the reusable kit and 2.5 L (95% CI, 2.1 to 2.9 l) for the single-use kit. For the reusable kit, sterilization had the greatest environmental cost, and for the single-use kit, the manufacture of plastic and metal components had the largest environmental costs. Different sources of electricity to make the reusable kits patient-ready again affected the CO(2) emissions: electricity from hospital gas cogeneration resulted in 436 g CO(2) (95% CI, 410 to 473 g CO(2)), from the United States electricity grid 764 g CO(2) (95% CI, 509 to 1174 g CO(2)), and from the European electricity grid 572 g (95% CI, 470 to 713 g CO(2)).ConclusionsInclusive of labor, the reusable central venous catheter insertion kits were less expensive than were the single-use kits. For our hospital, which uses brown coal-sourced electricity, the environmental costs of the reusable kit were considerably greater than those of the single-use kit. Efforts to reduce the environmental footprint of reusable items should be directed towards decreasing the water and energy consumed in cleaning and sterilization. The source of hospital electricity significantly alters the relative environmental effects of reusable items.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.