• J Hand Surg Am · Jan 2004

    Comparative Study

    Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation.

    • Martin I Boyer, Kenneth J Korcek, Richard H Gelberman, Louis A Gilula, Konstantinos Ditsios, and Bradley A Evanoff.
    • Department of Orthopaedic Surgery, Washington University School of Medicine at Barnes-Jewish Hospital, Suite 11300 West Pavilion, One Barnes Jewish Hospital Plaza, St Louis, MO 63110, USA.
    • J Hand Surg Am. 2004 Jan 1;29(1):116-22.

    PurposeTo compare anatomic tilt radiographs with standard posteroanterior (PA) and lateral radiographs for their efficacy in detecting screw penetration of the distal radius articular surface.MethodsTwenty-four cadaveric human forearm specimens had fixation with a dorsal distal radius plate and screws. Three groups were evaluated: (1) no articular surface screw penetration, (2) radial-sided articular screw penetration, and (3) ulnar-sided articular screw penetration. Standard PA and lateral views and anatomic tilt PA and lateral views were taken of each specimen. Three observers reviewed both individual (PA or lateral) and paired (PA and lateral) radiographs. These radiographs were evaluated based on whether or not articular penetration had occurred. A number between 1 and 5 was assigned to represent the degree of certainty of their assessment. The accuracy of the observers was calculated to determine if screw penetration of the articular surface had occurred and, if so, which screw had penetrated the joint. The sensitivity and specificity of each view, interobserver reliability, and the reviewers' confidence in evaluating presence or absence of screw penetration were calculated.ResultsThe use of anatomic tilt lateral views significantly improved the overall accuracy, (0.93 vs 0.64), sensitivity (0.98 vs 0.77), and specificity (0.83 vs 0.38) of the detection of articular screw penetration when compared with standard lateral views. PA and lateral anatomic tilt views, when viewed together, significantly improved (p <.001) the accuracy of each observer's determination of the position of the penetrated screw (0.90 vs 0.67). In addition, anatomic tilt views significantly improved the confidence of the reviewers in their more accurate observations (4.7 vs 3.3, p <.05).ConclusionsAnatomic tilt PA and lateral radiographs of the distal radius are an accurate and clinically useful tool for the evaluation of both presence and location of screw penetration of the articular surface after dorsal plating.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.