• J Hand Surg Am · May 2012

    Comparative Study

    Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius.

    • Kagan Ozer, Jennifer M Wolf, Bruce Watkins, and David J Hak.
    • Department of Orthopedic Surgery, University of Michigan, Ann Arbor, MI, USA. kozer@umich.edu
    • J Hand Surg Am. 2012 May 1;37(5):963-7.

    PurposeTo determine whether use of the dorsal tangential view improves the diagnostic accuracy of intraoperative fluoroscopy compared with conventional views in detecting dorsal screw penetrations during volar distal radius plating.MethodsDorsal cortices of 10 cadaveric distal radii were penetrated in each of the second, third, and fourth dorsal extensor compartments at 0, 1, 2, and 3 mm penetration. We obtained 4 standardized fluoroscopic images of the wrist: lateral, supination, pronation, and dorsal tangential views. Using high-definition digital images, 2 observers blinded to the experimental paradigm determined whether screws were penetrating the dorsal cortex.ResultsFor screws that penetrated the floor of the second dorsal compartment, the 45° supination view was 92% sensitive for detecting screw penetration of 2 mm, and 98% for 3 mm. For screws that penetrated the third dorsal compartment, the lateral view was 68% and 80% sensitive in detecting screw penetrations of 1 and 2 mm, respectively. However, the dorsal tangential view showed 95% sensitivity for 1 mm and 98% for 2 mm penetrations. On the floor of the fourth dorsal compartment, pronation and dorsal tangential views were both 88% sensitive for 1 mm screw penetration and 90% and 93% for 2 mm, respectively.ConclusionsThe standard lateral view of the wrist failed to detect all screw penetrations. The dorsal tangential view increased the accuracy of detecting screw penetrations on the floor of the third dorsal compartment, whereas we needed oblique views to detect screw penetrations on the floors of second and fourth dorsal compartments.Clinical RelevanceRoutine clinical use of the dorsal tangential view has the potential to increase accuracy in detecting dorsal screw penetration during volar plating of the distal radius.Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…