• Anaesthesia · Jul 1990

    Comparative Study

    Maintenance of body temperature in elderly patients who have joint replacement surgery. A comparison between the heat and moisture exchanger and heated humidifier.

    • P C Yam and F Carli.
    • Department of Anaesthesia, Northwick Park Hospital and Clinical Research Centre, Harrow, Middlesex.
    • Anaesthesia. 1990 Jul 1;45(7):563-5.

    AbstractThe effect of a heat and moisture exchanger on intra-operative aural canal (core) and mean skin temperatures was investigated in elderly patients who had elective total hip arthroplasty under general anaesthesia with artificial ventilation of the lungs. Group 1 (n = 20) did not receive any form of artificial humidification while in group 2 (n = 20) a heat and moisture exchanger was inserted in the breathing system and in group 3 (n = 20) the inspired gases were humidified and warmed at 40 degrees C by means of a heated humidifier. Time of surgery, intravenous fluid administration and operating theatre temperature were standardised. Mean (SD) aural canal (core) temperature decreased significantly in groups 1 and 2 (p less than 0.001), while there was a fall of 0.3 degrees C (0.6) in group 3, which was not significant. Mean skin temperature decreased during anaesthesia and surgery in both groups 1 and 2 (p less than 0.05), while it increased in group 3. There was a significantly greater loss of body heat in groups 1 and 2 compared with group 3 intra-operatively (p less than 0.001). We conclude tha a heat and moisture exchanger did not prevent the decrease in intra-operative body temperature in elderly patients.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.