• Spine J · Sep 2003

    Case Reports

    Somatosensory evoked potential monitoring of lumbar pedicle screw placement for in situ posterior spinal fusion.

    • Mukund Gundanna, Mark Eskenazi, John Bendo, Jeffrey Spivak, and Ronald Moskovich.
    • Department of Orthopaedic Surgery, New York University Hospital for Joint Diseases, 301 East 17th Street, New York, NY 10017, USA.
    • Spine J. 2003 Sep 1;3(5):370-6.

    Background ContextSomatosensory evoked potentials (SSEP) are commonly used to monitor the spinal cord and nerve roots during operative procedures that put those structures at risk. The utility of SSEPs to evaluate cauda equina and nerve root function during posterior spinal arthrodesis with pedicular fixation for degenerative lumbar disease has been reported anecdotally and remains controversial.PurposeAn institution-wide review of the ability of SSEP readings to monitor nerve function during posterior lumbar spinal arthrodeses with transpedicular fixation for degenerative lumbar spinal disorders was undertaken.Study Design/SettingA retrospective review was undertaken. Patient history, preoperative physical examination, intraoperative anesthesia, SSEP records and the postoperative course were reviewed.MethodsA total of 186 consecutive arthrodeses as described above were reviewed. Patients who had anterior procedures, spondyloreduction or scoliosis correction were excluded from the study. There were 76 male and 110 female patients. Five fellowship-trained spine surgeons placed a total of 888 pedicle screws. Sixty-five percent of the patients had a principal preoperative diagnosis of spinal stenosis with degenerative spondylolisthesis. Other common diagnoses were isthmic spondylolisthesis and degenerative scoliosis. Ninety-three percent of the cases involved decompressive laminectomy. Eight percent had posterior interbody fusions. All pedicle screws were placed without the assistance of fluoroscopy or stereotactic computer-assisted guidance. Screw position was evaluated intraoperatively with standard posteroanterior and lateral radiographs. Anesthetic agents compatible with SSEP monitoring were used in all patients. SSEP baseline readings were obtained in all patients in the operating room soon after induction of general anesthesia. An acute and sustained loss of 50% of the SSEP amplitude and/or increase by 10% of latency from baseline was considered to be pathologic.ResultsNone of the 186 patients had significant SSEP changes. There were, however, 5 patients with postoperative radiculopathies distinct from their preoperative presentations. Early postoperative plain radiographs and computed assisted tomography (CAT) scans revealed malpositioned pedicle screws. Consequently, eight pedicle screws were either revised or removed. All patients had partial or full recovery of their new deficits after revision surgery.ConclusionWe conclude that the use of SSEPs in evaluating pedicle screw placement during lumbar arthrodesis is limited. In this setting, if monitoring is required, alternative methods with greater sensitivity and efficacy should be explored.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…