• J. Cardiothorac. Vasc. Anesth. · Feb 2007

    Clinical Trial

    Effect of polymer coating (poly 2-methoxyethylacrylate) of the oxygenator on hemostatic markers during cardiopulmonary bypass in children.

    • Michael J Eisses, Jeremy M Geiduschek, Christer Jonmarker, Gordon A Cohen, and Wayne L Chandler.
    • Department of Anesthesiology and Pain Medicine, University of Washington School of Medicine, Seattle, WA 98105, USA. michael.eisses@seattlechildrens.org
    • J. Cardiothorac. Vasc. Anesth. 2007 Feb 1;21(1):28-34.

    ObjectiveHeparin and other oxygenator coatings have been used in attempts to reduce hemostatic activation during cardiopulmonary bypass (CPB). This study evaluated whether an oxygenator coated with poly 2-methoxyethylacrylate (PMEA) (X-coating; Terumo Corporation, Tokyo, Japan) would cause less activation of coagulation and fibrinolytic systems during CPB in children than a noncoated oxygenator.DesignObservational study.SettingUniversity-affiliated children's hospital.PatientsTwenty-six patients, 3 months to 5 years old, who underwent congenital heart surgery for repair of a ventricular septal defect, atrial septal defect, or both.InterventionsPatients were divided into 2 age-matched groups based on the type of oxygenator used: a noncoated oxygenator (group NC) versus a PMEA-coated oxygenator (group C).Measurements And Main ResultsBlood samples for coagulation and fibrinolytic markers were compared before, during, and after CPB. Despite increases in thrombin generation markers (F1.2 and TAT) at certain times during CPB in group C compared to group NC, a comparison over all times during CPB were not statistically different between groups. Overall D-dimer concentrations during CPB were elevated in group C compared to group NC (p = 0.02). Active tPA and active PAI-1 were not different between groups during or after CPB. Group C had higher platelet counts (181,000 +/- 29,000) during CPB than group NC (155,000 +/- 57,000, p = 0.04) but not postoperatively. Twelve hours postoperatively, chest tube outputs were 8.8 +/- 3 mL/kg in group C and 19.1 +/- 12 mL/kg in group NC (p = 0.003). The corresponding outputs 24 hours after surgery were 12.4 +/- 3 mL/kg and 24 +/- 11 mL/kg, respectively (p = 0.005).ConclusionsExcept for a somewhat higher platelet count during CPB, there was no indication that PMEA coating resulted in less activation of coagulation and fibrinolytic systems. The lower postoperative chest tube output observed after CPB with PMEA-coated oxygenators needs to be studied further.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.