• Anesthesiology · Aug 2010

    Comparative Study

    Lumbar intrathecal administration of the quaternary lidocaine derivative, QX-314, produces irritation and death in mice.

    • Stephan K W Schwarz, Helen M-C Cheung, Craig R Ries, Sang Mook Lee, Jimmy T C Wang, and Bernard A MacLeod.
    • St. Paul's Hospital, Vancouver, British Columbia, Canada. stephan.schwarz@ubc.ca
    • Anesthesiology. 2010 Aug 1;113(2):438-44.

    BackgroundWe recently found that peripheral administration of the quaternary lidocaine derivative, QX-314, produces long-lasting sensory and motor blockade in animals. The goal of this study was to test whether intrathecal QX-314 has similar properties.MethodsWe conducted a randomized, double-controlled, blinded study with female CD-1 mice. Animals in the treatment group received lumbar intrathecal QX-314 (0.5-10 mM; volume, 2 microl; each concentration, n = 6). Normal saline and lidocaine (70 mM) served as negative and positive controls (each group, n = 12), respectively. Animals were tested for up to 3 h for lumbosacral neural blockade and observed for adverse effects.ResultsNo animal injected with saline and 11 of 12 (92%) animals injected with lidocaine displayed reversible lumbosacral motor blockade (P < 0.001). QX-314 (5 mM) produced motor blockade in four of the six (67%) and sensory blockade in five of the six animals (83%; P < 0.05 vs. saline). However, six of the six mice (100%) at 5 mM QX-314 and five of the six (83%) at 10 mM exhibited marked irritation; one of the six animals at 5 mM (17%) and two of the six at 10 mM (33%) died. We observed no neural blockade without adverse effects in any animal injected with QX-314. All animals injected with saline and 11 of the 12 (92%) animals injected with lidocaine demonstrated normal behavior.ConclusionLumbar intrathecal QX-314 concentration-dependently produced irritation and death in mice, at lower concentrations than those associated with robust motor blockade. Although QX-314 did produce long-lasting neural blockade, these findings indicate that QX-314 is unlikely to be a suitable candidate for spinal anesthesia in humans.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…