• Int J Obstet Anesth · May 2014

    Randomized Controlled Trial Comparative Study

    A randomized, observer-blind comparison between the Neurotip mounted Neuropen and a disposable plastic neurological wheel for assessing the level of spinal blockade at cesarean section.

    • J A Wolin, T R Carter, C L Baysinger, X Han, M Shotwell, and J W Downing.
    • Department of Anesthesiology, Vanderbilt University School of Medicine, Nashville, TN, USA.
    • Int J Obstet Anesth. 2014 May 1;23(2):125-30.

    BackgroundVarious methods are used to assess the height of sensory block to touch under spinal anesthesia for cesarean section. We tested a novel, inexpensive, miniature, user-dependent plastic neurological wheel against the user-independent Neurotip mounted Neuropen.MethodsPatients received either spinal or combined spinal-epidural anesthesia. For each patient assessment, the devices were randomly assigned to one of two independent investigators. The order of device application was randomly permuted. Neither researcher was involved with anesthetic care. At 5-min intervals for 20 min after spinal injection, and again at the end of the operation, the levels of block to loss-of-touch sensation were assessed. While one investigator evaluated the block, the other left the operating room and vice versa. Mixed-effects regression and Bland-Altman analysis were used to weigh agreement between devices.ResultsThe mean difference in level-to-touch was 0.04 (95% CI -0.18, 0.27) dermatome levels. Measurement error standard deviation associated with the Neurotip mounted Neuropen and plastic neurological wheel was 1.36 (95% CI 1.26, 1.41) and 1.33 (95% CI 1.26, 1.46) dermatome levels, respectively. The difference in measurement error standard deviation was -0.03 (95% CI -0.16, 0.24). This evidence excludes the possibility, with 95% confidence, of clinically significant bias or measurement error differences between methods. Occasional wide variances in dermatome level were observed with both instruments at the initial assessment only.ConclusionThe compact plastic neurological wheel is as clinically reliable as the Neurotip mounted Neuropen.Copyright © 2013 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…