• J Spinal Disord Tech · Jun 2015

    Measurement of Thoracic Inlet Alignment on MRI: Reliability and the Influence of Body Position.

    • Jun Qiao, Feng Zhu, Zhen Liu, Leilei Xu, Zezhang Zhu, Bangping Qian, Xu Sun, Qing Jiang, and Yong Qiu.
    • *Department of Spine Surgery, the Affiliated Drum Tower Hospital of Nanjing University Medical School †The Center of Diagnosis and Treatment for Joint Disease, the Affiliated Drum Tower Hospital of Nanjing University Medical School.
    • J Spinal Disord Tech. 2015 Jun 18.

    Study DesignA retrospective radiographic study.ObjectiveTo investigate the reliability of using MRI to measure thoracic outlet parameters and whether supine MRI could supersede upright X-ray in measuring these parameters.Summary Of Background DataIn X-ray, overlapped soft and bony tissues make sternum contour invisible. Thus, measuring thoracic inlet alignment in X-ray may be inaccurate. MRI could clearly show anatomy around thoracic inlet.MethodsOne hundred and twenty-four adolescents with idiopathic thoracolumbar/lumbar scoliosis were recruited. The visibility of T1 upper end plate and the upper end of sternum in the lateral standing X-ray films was rated. For patients with moderate or good clarity forT1 upper end plate and the upper end of sternum on X-ray films, thoracic inlet angle (TIA), T1 slope (T1S) and neck tilt (NT) were measured by 3 observers on standing X-ray films and supine MR images, respectively. Intraclass correlation coefficients were used to determine the intraobserver, interobserver and method reliability. Paired t test was performed to compare the measurements between the two methods. The correlation coefficients between the two methods were analyzed by regression analysis.ResultsThe visibility of thoracic inlet region in X-ray films was unsatisfactory, whereas all the landmarks were clear in MR images. Only 81 patients' X-ray films were graded as moderate or good visibility in the thoracic inlet region. Both the intraobserver ICC and interobserver ICC were better in the MRI set than in the X-ray set in all the observers for three TI parameters. Paired t test demonstrated that no significant difference was noted in terms of TIA, T1S and TN (P=0.572, 0.203 and 0.637, respectively). Regression analysis demonstrated high correlation coefficients for TIA, T1S and NT (R=0.612, 0.629 and 0.722, respectively).ConclusionMRI serves as a good substitute for X-ray scans with regard to the measurement of TI alignment, with superior reliability.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.