-
Pediatr Crit Care Me · Oct 2000
Assessment of respiratory drive and muscle function in the pediatric intensive care unit and prediction of extubation failure.
- T I Manczur, A Greenough, D Pryor, and G F Rafferty.
- Department of Child Health, King's College Hospital, London, UK.
- Pediatr Crit Care Me. 2000 Oct 1;1(2):124-6.
BackgroundExtubation failure can result from poor respiratory drive, impaired respiratory muscle function, or excessive inspiratory load. Measurement of airway pressure changes either during tidal breathing or after end-expiratory occlusion allows assessment of respiratory drive and muscle function.ObjectiveTo determine whether the results of airway pressure measurements characterized children who subsequently failed extubation and identify which test's results had the highest predictive performance.DesignA prospective study.SettingPediatric intensive care unit.PatientsA sample of 42 stable intubated pediatric patients who were judged clinically ready for extubation.MethodsA pneumotachograph was placed between the endotracheal tube and ventilator circuit. Airway pressure was measured from the pneumotachograph. The flow and pressure signals were amplified and displayed in real time on a laptop computer. During a temporary disconnection from the ventilator, the airway was occluded at end-expiration and the occlusion maintained for at least five breaths. From the first inspiratory effort during the occlusion, the pressure generated after 0.1 sec of occlusion (P0.1) and the largest negative pressure (PI) were calculated. From the series of breaths during the occlusion, the maximum P0.1 (P0.1 max) and maximum PI (PI max) were determined and P0.1/P0.1 max, PI/PI max and P0.1/PI max calculated. From spontaneous, tidal breaths during ventilatory support the pressure time product was calculated.ResultsThirty-six (84%) of the children were successfully extubated. The children who failed extubation were characterized by a lower median P0.1 (p <.06), P0.1/P0.1 max, p <.05 and P0.1/PI max (p <.02). P0.1 and P0.1/P0.1 max and performed best in predicting extubation failure (areas under the receiver operator characteristic curves, 0.76 and 0.77 respectively).ConclusionAssessment of P0.1 was the most useful airway pressure measurement in predicting extubation failure. Assessment of P0.1 may help to characterize children likely to fail extubation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.