• J. Am. Coll. Cardiol. · May 2007

    Multicenter Study Clinical Trial

    Coronary sinus reducer stent for the treatment of chronic refractory angina pectoris: a prospective, open-label, multicenter, safety feasibility first-in-man study.

    • Shmuel Banai, Shmuel Ben Muvhar, Keyur H Parikh, Aharon Medina, Horst Sievert, Ashok Seth, Jonathan Tsehori, Yoav Paz, Ami Sheinfeld, and Gad Keren.
    • Cardiology Department, Tel Aviv Medical Center, Tel Aviv, Israel. banais@netvision.net.il
    • J. Am. Coll. Cardiol. 2007 May 1;49(17):1783-9.

    ObjectivesThis study sought to evaluate the safety of the Coronary Sinus Reducer (Neovasc Medical, Inc., Or Yehuda, Israel) as a potential alternate therapy for patients with refractory angina who are not candidates for conventional revascularization procedures.BackgroundIncreased coronary sinus (CS) pressure can reduce myocardial ischemia by redistribution of blood from nonischemic to ischemic territories. The Coronary Sinus Reducer is a percutaneous implantable device designed to establish CS narrowing and to elevate CS pressure. In preclinical experiments, implantation of the Reducer was safe and was associated with improved ischemic parameters. In the present study, the safety and feasibility of the Coronary Sinus Reducer was evaluated in patients with refractory angina who were not candidates for revascularization.MethodsFifteen coronary artery disease patients with severe angina and reversible ischemia were electively treated with the Reducer. Clinical evaluation, dobutamine echocardiography, thallium single-photon emission computed tomography, and administration of an angina questionnaire were performed before and 6 months after implantation. Cardiac computed tomography was performed 2 days and 6 months after implantation.ResultsAll procedures were completed successfully. No procedure-related adverse events occurred during the periprocedural and the follow-up periods. Angina score improved in 12 of 14 patients. Average Canadian Cardiovascular Society score was 3.07 at baseline and 1.64 at follow-up (n = 14, p < 0.0001). Stress-induced ST-segment depression was reduced in 6 of 9 patients and was eliminated in 2 of these 6 (p = 0.047). The extent and severity of myocardial ischemia by dobutamine echocardiography and by thallium single-photon emission computed tomography was reduced (p = 0.004 [n = 13] and p = 0.042 [n = 10], respectively).ConclusionsImplantation of the Coronary Sinus Reducer is feasible and safe. These findings, along with the clinical improvement observed, support further evaluation of the Reducer as an alternative treatment for patients with chronic refractory angina who are not candidates for coronary revascularization.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.