- Julio C Furlan, Michael G Fehlings, Eric M Massicotte, Bizhan Aarabi, Alexander R Vaccaro, Christopher M Bono, Ignacio Madrazo, Carlos Villanueva, Jonathan N Grauer, and David Mikulis.
- Spinal Program, Krembil Neuroscience Centre, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
- Spine. 2007 Sep 1;32(19):2083-91.
Study DesignReliability study.ObjectiveTo assess the intrarater and interrater reliability of a recently described technique to measure of maximum canal compromise (MCC) and maximum spinal cord compression (MSCC) using digitized and magnified images in the setting of traumatic cervical spinal cord injury (SCI).Summary Of Background DataThe extent of MCC and MSCC is of clinical and prognostic value in the setting of traumatic cervical SCI. However, concerns remain regarding the accuracy of measurements based on hard copy images. We hypothesized that the interrater and intrarater reliability of these assessments would be enhanced using magnified digitized images and software-based measurement tools.MethodsMidsagittal MRI and CT images of cervical spine were selected from 5 individuals with acute traumatic cervical SCI. Measurements of MCC using CT scan and T1-weighted MRI and measurements of MSCC based on T2-weighted MR images were independently estimated by 13 raters on 10 occasions.ResultsThe intrarater reliability for CT-MCC, T1-weighted MRI-MCC and T2-weighted MRI-MSCC was high in the 10 rounds in each patient. In addition, the mean intrarater interclass correlation coefficient was 0.72 +/- 0.05 for the CT-MCC, 0.70 +/- 0.07 for the T1-weighted MRI-MCC, and 0.68 +/- 0.11 for the T2-weighted MRI-MSCC. The mean interrater interclass correlation coefficients were 0.43 +/- 0.02 for the CT-MCC, 0.61 +/- 0.03 for the T1-weighted MRI-MCC, and 0.55 +/- 0.05 for the evaluation of T2-weighted MRI-MSCC.ConclusionOur study has demonstrated that the intrarater reliability for the instrument to assess MCC and MSCC in the setting of traumatic SCI was high. The interrater ICCs at a moderate level of reliability combined with our results using analysis of variance with post hoc tests indicate that the measurements of MCC and MSCC are reproducible, which supports the use of these radiologic parameters in the clinical and research settings.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.