• Int J Comput Assist Radiol Surg · Aug 2015

    Axial perspective to find the largest intraosseous space available for percutaneous screw fixation of fractures of the acetabular anterior column.

    • XiaoReng Feng, JinTao Fang, Chaowen Lin, Sheng Zhang, WenXiong Lei, YuanHui Li, SanYuan Tang, and Bin Chen.
    • Department of Orthopedic Trauma, Nanfang Hospital, Southern Medical University, No. 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
    • Int J Comput Assist Radiol Surg. 2015 Aug 1; 10 (8): 1347-53.

    ObjectiveTo find the largest screw path in the acetabular anterior column using a novel method of axial perspective and test the clinical feasibility of the anterior column axial view projection.Methods3D models with the inner triangular patches deleted were created from the pelvic CT scan data of 58 normal pelvises. The transparency of each 3D model was downgraded at the axial perspective (the view perpendicular to the cross section of the anterior column axis) so that a translucent area was seen clearly. The orientations of each 3D model were adjusted until a triangle-like translucent area that could accommodate the largest virtual screw (Screw I) was present and then an ellipse-like translucent area that could accommodate the two largest virtual screws (Screw II) was present. The maximum diameter, direction of Screw I and the maximum diameter Screw II were measured. Clinical feasibility of the axial view projection was next tested in five cadaveric specimens.ResultsThe mean maximum diameters of Screw I and Screw II were 11.20 ± 1.73 (7.80-14.60 mm) and 8.71 ± 0.91 (6.60-10.60 mm), respectively. The angles of Screw I to the transverse, coronal and sagittal planes were 41.16° ± 4.59°, 18.18° ± 1.15° and 44.33° ± 4.31°, respectively. Translucent areas were successfully observed in all the cadaveric hemi-pelves and guide pins were successfully inserted in all the cadaveric hemi-pelves with the assistance of the anterior column axial view projection without cortex penetration or joint violation.ConclusionsThe acetabular anterior column could safely accommodate not only one 7.3-mm screw, but also two 6.5-mm screws. The anterior column axial projection may be clinically feasible.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…