• Der Anaesthesist · Aug 2001

    Case Reports

    [Unilateral high-frequency jet ventilation supporting one-lung ventilation during thoracic surgical procedures].

    • D Knüttgen, D Zeidler, M Vorweg, and M Doehn.
    • Abteilung für Anästhesiologie, Kliniken der Stadt Köln, Krankenhaus Merheim, Ostmerheimerstrasse 200, 51109 Köln.
    • Anaesthesist. 2001 Aug 1; 50 (8): 585-9.

    AbstractWe report two cases where surgery on the right lung had to be performed for resection of a malignoma. In both cases, function of the left lung was severely restricted. In the first patient, the volume on this side was reduced by around 50% as the result of a recently performed upper lobe resection. In the second patient, perfusion of the left lung accounted for only 18% of the total lung perfusion. On the basis of these changes we considered conventional one-lung ventilation impracticable and performed surgery using differential lung ventilation. The dependent (left) lung was ventilated by intermittent positive pressure ventilation (IPPV), where the tidal volume in the first patient had to be reduced to 200 ml because of high airway pressures. Ventilation of the non-dependent (right) side was performed simultaneously in both patients by means of high frequency jet ventilation (HFJV). Under this procedure arterial O2 saturation ranged from 96 to 100%, and arterial CO2 partial pressure was 45 mmHg. Surgery was not hindered by ventilation, the postoperative progress was also without complications. The case reports show that with the help of the ventilation regime described (operated side: HFJV, non-operated side: IPPV) lung surgery can be successfully performed on patients who are unsuitable for conventional one-lung ventilation for functional reasons.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…