    The impact of airway management on quality of cardiopulmonary resuscitation: an observational study in patients during cardiac arrest.

    • Joyce Yeung, Mehboob Chilwan, Richard Field, Robin Davies, Fang Gao, and Gavin D Perkins.
    • Heart of England NHS Foundation Trust, Birmingham Heartlands Hospital, Birmingham B9 5SS, United Kingdom; University of Birmingham, School of Clinical and Experimental Medicine, Birmingham B15 2TT, United Kingdom.
    • Resuscitation. 2014 Jul 1; 85 (7): 898-904.

    BackgroundMinimising interruptions in chest compressions is associated with improved survival from cardiac arrest. Current in-hospital guidelines recommend continuous chest compressions after the airway is secured on the premise that this will reduce no flow time. The aim of this study was to determine the effect of advanced airway use on the no flow ratio and other measures of CPR quality.MethodsConsecutive adult patients who sustained an in-hospital cardiac arrest were enrolled in this prospective observational study. The quality of CPR was measured using the Q-CPR device (Phillips, UK) before and after an advanced airway device (endotracheal tube [ET] or laryngeal mask airway [LMA]) was inserted. Patients receiving only bag-mask ventilation were used as the control cohort. The primary outcome was no flow ratio (NFR). Secondary outcomes were chest compression rate, depth, compressions too shallow, compressions with leaning, ventilation rate, inflation time, change in impedance and time required to successfully insert airway device.ResultsOne hundred patients were enrolled in the study (2008-2011). Endotracheal tube and LMA placement took similar durations (median 15.8 s (IQR 6.8-19.4) vs. LMA median 8.0s (IQR 5.5-15.9), p=0.1). The use of an advanced airway was associated with improved no flow ratios (endotracheal tube placement (n=50) improved NFR from baseline median 0.24 IQR 0.17-0.40) to 0.15 to (IQR 0.09-0.28), p=0.012; LMA (n=25) from median 0.28 (IQR 0.23-0.40) to 0.13 (IQR 0.11- 0.19), p=0.0001). There was no change in NFR in patients managed solely with bag valve mask (BVM) (n=25) (median 0.29 (IQR 0.18-0.59) vs. median 0.26 (IQR 0.12-0.37), p=0.888). There was no significant difference in time taken to successfully insert the airway device between the two groups.ConclusionThe use of an advanced airway (ETT or LMA) during in-hospital cardiac arrest was associated with improved no flow ratio. Further studies are required to determine the effect of airway devices on overall patient outcomes.Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…