- J M Miles and G R Thompson.
- Anaesthesia. 1987 Apr 1;42(4):415-8.
AbstractTwo cases of severe accidental hypothermia (core temperature less than 28 degrees C) rewarmed employing the Clinitron system are described. The physiological changes during hypothermia and rewarming are discussed and the current concepts of rewarming (active external versus internal) outlined. It is suggested that severely hypothermic patients can be successfully treated by rapid external rewarming using the Clinitron heated fluidised-bead bed. This method combines the advantages of rapid rewarming, minimal physiological disturbance and is non invasive.